40 WATTS

    NO MINIMUM ORDER REQUIRED

SRP-40A SERIES

     

 OUTPUT SPECIFICATIONS  
Features
  •  RoHS Compliant
  •  Universal 85-264 VAC Input
  • Advanced SMT Design
  • Compact 2.5" X 4.25" X 1.2" Size
  • Class B Emissions Per EN 55011/22
  • EMC to EN 61000-6-2 & EN 60601-1-2
  • 2 Year Warranty
  • Fits 1U Application
  • EN 60950 ITE Certification
  • EN 60601-1 Medical Certification
  • Optional Chassis & Cover
  • One to Four Outputs

Total Output Power 40 W (33W, 1001)
Output Voltage Centering Output 1: +/-0.25%
Output 2: +/-5.0%
Output 3: +/-3.0%
Output 4: +/-3.0%
(All outputs at 50% load)
Source Regulation Outputs 1-4: 0.5%
Load Regulation    
Output 1: 0.5% (10-100% Load Change)
Output 2: 5.0% (30-100% Load Change)
(2003, 4002)  7.0% (30-100% Load Change)
Output 3:  0.5% (10-100% Load Change)
Output 4:  0.5% (10-100% Load Change)
Cross Regulation Output 2: 5.0%
Output 3: 0.5%
Output 4: 0.5%
(Output 1 load varied 50-100%)
Output Voltage Adjust Range  Output 1: 95% to 105%
Output Noise Outputs 1-4: 1.0%
   
Turn On Overshoot None
Transient Response Outputs 1-4
Volt. Deviation 5.0%
Recovery Time 2 mS
Load Change 50% To 100%
Output Overvoltage Protection Output 1: 110% to 150%
Output Overpower Protection Output 1&2  110% Min.
Outputs cycle on/off, auto recovery
Output Overcurrent Protection Output 3&4      110% Min.
Hold Up Time 10 mS Min, 40 W Output
120 V Input
Start Up Time 1 Second
   INPUT SPECIFICATIONS  
Source Voltage 85-264 Voltage AC
Frequency Range 47-63 Hz
Source Current  
True RMS 1A At 85V Input
Peak Inrush 30A
Efficiency .66 -.80 (Varies by model)
   ENVIRONMENTAL SPECIFICATIONS  
Ambient Operating Temperature Range 0oC to +70oC    Derating: See Power Rating Chart
Ambient Storage Temperature Range -40oC to +85oC
Temperature Coefficient Outputs 1-4: 0.02%/oC

   SAFETY SPECIFICATIONS  
   GENERAL SPECIFICATIONS  
General   Protection Class:

I

Overvoltage Category:

II

Pollution Degree:

2

 

 

 

Underwriters
Laboratories
File E137708/E140259

UL 60950-1 First Edition                UL 60601 - 1 First  Edition


CB Report Per IEC 60950-1(2001)
First Edition         All National Deviations
CB Report Per IEC 60601-1(1988)
First Edition, A1, A2

 
UL Recognition Mark for Canada
File E137708/E140259
CAN/CSA-C22.2 No. 60950-1-03
CAN/CSA-C22.2 No. 601-1-M90 with updates 1 and 2
 
TUV EN 60950-1:2001               EN 60601-1/A2: 1995  
  Low Voltage Directive  
Dielectric Strength  
    Reinforced          Insulation  5656 VDC, Primary to Secondary, 1 Sec.
Basic Insulation 2121 VDC, Primary to Ground, 1 Sec.

Operational Insulation

707 VDC, Secondary to Ground, 1 Sec.
Leakage Current <300 µA Earth Leakage Current
Mean Time Between Failures 100,000 Hours min., MIL-HDBK-217F, 25oC, GB
Weight 0.85 Lbs.  Chassis and Cover
0.49 Lbs.  Open Frame
  ELECTROMAGNETIC COMPATIBILITY
Electrostatic Discharge EN 61000-4-2  +/-8kV Contact Discharge
+/-8kVAir Discharge
Radiated Electro-magnetic Field EN 61000-4-3  80MHz-2.5GHz, 10V/m, 80% AM
EFT/Bursts EN 61000-4-4  +/-2kV
Surges EN 61000-4-5  +/-1 kV Differential Mode
+/-2 kV Common Mode
Conducted Immunity EN 61000-4-6  .15-80MHz., 10V, 80% AM
Voltage Dips and Interruptions EN 61000-4-11 30% Reduction,500ms
95% Reduction,10ms
60% Reduction,1s (Criteria B)
95% Reduction,5000ms
Radiated Emissions EN 55011/22 Class B
Conducted Emissions EN 55011/22 Class B
   Notes  

Consult factory for alternate output configuration.
Consult factory for positive, negative or floating output 2.
Refer to Application Information for complete output power ratings.

All specifications are maximum at 25C unless otherwise stated and are subjected to change without notice.
Specify optional chassis and cover when ordering.

TUV only: SRP-40A-3003

   MODEL LISTING
Model Output 1 Output 2 Output 3 Output 4 Max Power
SRP-40A-4001 +3.3V/5A +5V/3A +12V/.7A -12V/.7A 40W
SRP-40A-4002 +5V/5A +3.3V/3A +12V/.7A -12V/.7A 40W
SRP-40A-4003 +5V/5A -5V/3A +12V/.7A -12V/.7A 40W
SRP-40A-4004 +5V/5A -5V/3A +15V/.7A -15V/.7A 40W
SRP-40A-4005 +5V/5A +24V/1.5A +12V/.7A -12V/.7A 40W

SRP-40A-4006

SRP-40A-4007

+5V/5A

+3.3V/3.1A

+24V/1.5A

+5V/1.25A

+15V/.7A

-24V/.27A

-15V/.7A

-51.6V/.25A

40W
SRP-40A-3001 +5V/5A +12V/2A -12V/.7A   40W

SRP-40A-3002

SRP-40A-3003

SRP-40A-3004

SRP-40A-3005

+5V/5A

+24V/1.5A

+14.5V/1.5A

+5.1V/5A

+15V/2A

 

-14.5V/1.5A

+15V/2A

-15V/.7A

+15V/0.7A

+5V/1A

+9V/0.7A

 

-15V/0.7A

 

 

40W
SRP-40A-2001 +5V/5A +24V/1.5A     40W
SRP-40A-2002 +5V/5A +12V/3A     40W
SRP-40A-2003 +5V/5A -5V/4A     40W
SRP-40A-2004 +12V/3A -12V/3A     40W

SRP-40A-2005

SRP-40A-2006

SRP-40A-2007

SRP-40A-2008

+15V/2.5A

+30V/1.2A

+3.3V/5A

+6V/5A

-15V/2A

 

 

+9V/1.1A

 

-15V/0.7A

+5V/0.7A

 

 

 

 

 

40W
SRP-40A-1001 3.3V/10A       33W
SRP-40A-1002 5V/8A       40W
SRP-40A-1003 12V/3.33A       40W
SRP-40A-1004 15V/2.67A       40W
SRP-40A-1005 24V/1.67A       40W

SRP-40A-1006

SRP-40A-1007

48V/0.83A

9V/4.45A

 

 

 

 

 

 

40W

 

   SRP-40A SERIES MECHANICAL SPECIFICATIONS  

   APPLICATIONS INFORMATION
  1. Each output can deliver its rated current but total output power must not exceed
    40 watts(33W, 1001). 
  2. Maximum ambient temperature is reduced to 40 C with optional chassis and cover.
  3. Semiconductor case temperature must not exceed 110 C
  4. Sufficient area must be provided around convection cooled power supplies to allow natural movement of air develop.
  5. This product is intended for use as a professionally installed component within information technology and medical equipment.
  6. A minimum load of 10% is required on output one to insure proper regulation of remaining outputs.
  7. Remote sense terminals may be used to compensate for cable losses up to 250mV. The use of a twisted pair is recommended as well as a decoupling capacitor (0.1 0 10microF) and a capacitor of 100microF/amp connected across the load.
  8. Peak to peak output ripple and noise is measured directly at the output
    terminals of the power supply, without the use of the probe ground lead or retractable tip, 20 MHz bandwidth.
  9. This product is use only one fuse in the input circuit. In consideration of clause 57.6 of UL 2601-1, a second fuse may be required in the end product.
  10. This product was type tested and safety certificated using the the dielectric strength test voltages listed in Table V of UL 60601-1. In consideration of clause 20.4g, care must be taken to insure the voltage applied to a reinforced insulation does not over stress basic insulation. Secondary to ground capacitors may need to be removed prior to performing a dielectric strength type test on the end product. It is highly recommended that the DC test voltages listed in DVB.1. Annex DVB are not exceeded during a production-line dielectric strength test of the assembled end product. Please consult factory for further information.
 
  1. This power supply has been safety approved and final tested using a DC
    dielectric strength test. Please consult factory before performing AC dielectric strength test.
  2. Maximum screw penetration into bottom chassis mounting holes is .100 inches.
  3. Maximum screw penetration into side chassis mounting holes is .250 inches.
  4. To meet emissions specifications, all four mounting hole pads must be electrically connected to a common metal chassis. Chassis/Cover option recommended.
 

 Maximum Output Power vs. Ambient Temperature

   CONNECTOR SPECIFICATIONS
P1 AC Input

.156 friction lock header mates with Molex 09-50-3031 or equivalent crimp terminal housing with Molex 08-50-0189 or equivalent crimp terminal.

P3 DC Output(Single) .156 friction lock header mates with Molex 09-50-3061 or equivalent crimp terminal housing with Molex 08-50-0189 or equivalent crimp terminal.
P3 DC Output(Multiple) .156 friction lock header mates with Molex 09-50-3081 or equivalent crimp terminal housing with Molex 08-50-0189 or equivalent crimp terminal.
P4,P5

Sense

.100 friction lock header mates with Molex 22-01-2027 or equivalent crimp terminal housing with Molex 08-50-0114 or equivalent crimp terminal.
G Ground .187 quick disconnect terminal.
   RECOMMENDED AIR FLOW DIRECTION
  1. Optimum
  2. Good
  3. Fair
   