65 WATTS

    NO MINIMUM ORDER REQUIRED

SRW-65 SERIES

     

 OUTPUT SPECIFICATIONS  
Features
  • RoHS 
  • Universal 85-264 VAC Input 
  • Compact 4.0" X 6.0" X 1.1" Size
  • Class B Emissions Per EN 55022
  • 2 Year Warranty
  • Fits 1U Application
  • EN 60950-1 ITE Certification
  • One to Four Outputs
  • Optional Chassis & Cover

Total Output Power at 500 C 65 W
Output Voltage Centering Output 1: +/-1.0%
Output 2: +/-5.0%
Output 3: +/-5.0%
Output 4: +/-5.0%
(All outputs at 50% load)
Source Regulation Outputs 1-4: 0.5%
Load Regulation
Output 1:  1.0% (10-100%Load Change)
Output 2: 5.0% (20-80% Load Change)
Output 3: 5.0% (20-80% Load Change)
Output 4: 5.0% (20-80% Load Change)
Cross Regulation Output 2: 5.0%
Output 3: 5.0%
Output 4: 5.0%
(Output 1 load varied 50-100%)
Output Voltage Adjust Range Output 1: 95% to 105%
Output Noise Outputs 1-4: 1.0%
   
Turn On Overshoot None
Transient Response Outputs 1-4
Volt. Deviation 5.0%
Recovery Time 2 mS
Load Change 50% To 100%
Output Overvoltage Protection (Optional) Output 1: 110% to 150%
Output Overpower Protection Output 1-4  110% Min.
Outputs cycle on/off, auto recovery
Hold Up Time 16 mS Min, 65 W Output
120 V Inputt
Start Up Time 1 Second
   INPUT SPECIFICATIONS  
Source Voltage 85-264 Voltage AC
Frequency Range 47-63 Hz
Source Current  
True RMS 1.5A At 85V Inputut
Peak Inrush 40A
Efficiency .72 -.80 (Varies by model)
   ENVIRONMENTAL SPECIFICATIONS  
Ambient Operating Temperature Range 0oC to +70oC    Derating: See Power Rating Chart
Ambient Storage Temperature Range -40oC to +85oC
Temperature Coefficient Outputs 1-4: 0.02%/oC
Conducted Emissions EN 55022 Class B

   SAFETY SPECIFICATIONS  
   GENERAL SPECIFICATIONS  
General   Protection Class:

I

Overvoltage Category:

II

Pollution Degree:

2

Underwriters
Laboratories
File E137708
UL 60950-1 First Edition  
UL Recognition Mark for Canada
File E137708
CAN/CSA-C22.2 No. 60950-1-03  
TUV EN 60950-1:2001  

 

Low Voltage Directive

CB Report per IEC 60950-1(2001)      First Edition            All National Deviations

 
    
Dielectric Strength  
Reinforced Insulation 4242 VDC, Primary to Secondary, 1 Sec.
Basic Insulation 2121 VDC, Primary to Ground, 1 Sec.

Operational Insulation

500 VDC, Secondary to Ground, 1 Sec

Mean Time Between Failures 150,000 Hours min., MIL-HDBK-217F, 25oC, GB

Weight

 

Power Fail Signal (Optional)

1.65 Lbs.  Chassis and Cover
0.80 Lbs.  Open Frame

Logic low with input power failure, 2mS minimum prior to output 1 dropping 1%

   MODEL LISTING
Model Output 1 Output 2 Output 3 Output 4
SRW-65-4001 +5V/5A -5V/3A +12V/2A -12V/2A
SRW-65-4002 +5V/5A +12V/1A +12V/2A -12V/2A
SRW-65-4003 +5V/5A +24V/1A +12V/2A -12V/2A
SRW-65-4004 +5V/5A -5V/3A +15V/2A -15V/2A
SRW-65-4005 +5V/5A +24V/1A +12V/2A -5V/2A
SRW-65-4006 +5V/5A +24V/1A +15V/2A -15V/2A
SRW-65-4007 +5V/5A +26V/1A +15V/2A -15V/2A
SRW-65-4008 +5V/5A +24V/1A +12V/2A -12V/2A
SRW-65-4009 +5V/7.5A +48V/.25A +15V/1A -15V/1A
SRW-65-4103 +5V/5A 26V/1A +12V/2A -12V/2A
SRW-65-4104 +5V/4A 5V/.25A +15V/2.5A 24V/.5A
SRW-65-3001 +5V/5A   +12V/3A -12V/1A
SRW-65-3002 +5V/7A   +12V/2A -12V/2A
SRW-65-3003 +5V/7A   +15V/2A -15V/2A
SRW-65-3004 +5V/5A -5V/4A +12V/2A  
SRW-65-3005 +5V/5A -5V/4A +24V/1A  
SRW-65-3006 +5.25V/6A +15V/1A +34V/1.5A  
SRW-65-2001 +5V/7A     -5V/5A
SRW-65-2002 +5V/7A   +12V/3A  
SRW-65-2003 +12V/3A     -12V/2.5A
SRW-65-2004 +15V/2.5A     -15V/2A
SRW-65-2005 +5V/7A   +24V/1.5A  
SRW-65-2006 +5V/9A   +12V/2A  
SRW-65-2008 +6V/5A     -6V/5A
SRW-65-1001 5V/13A      
SRW-65-1002 12V/5.4A      
SRW-65-1003 15V/4.3A      
SRW-65-1004 24V/2.7A      

SRW-65-1005

SRW-65-1006

SRW-65-1104

SRW-65-1105

18V/3.6A

24V/3.33A

24V/3.33A

21V/3.1A

     
     
     
   Notes
  Consult factory for alternate output configuration.
Consult factory for positive, negative or floating outputs.
Refer to Application Information for complete output power ratings.
All specifications are maximum at 25C unless otherwise stated and are subjected to change without notice.
Specify optional chassis and cover, power fail, overvoltage protection, transient protection or DC Input when ordering.

TUV only:SRW-65-2008
   SRW-65 SERIES MECHANICAL SPECIFICATIONS  

 

   APPLICATIONS INFORMATION
  1. Each output can deliver its rated current but total output power must not exceed
    65 watts. 
     
  2. Semiconductor case temperature must not exceed 110 C
  3. Sufficient area must be provided around convection cooled power supplies to allow natural movement of air develop.
  4. This product is intended for use as a professionally installed component within information technology and medical equipment.
  5. A minimum load of 20% is required on output one to insure proper regulation of remaining outputs.  
  6. Peak to peak output ripple and noise is measured directly at the output
    terminals of the power supply, without the use of the probe ground lead or retractable tip, 20 MHz bandwidth.
     
  7. This product was type tested and safety certificated using the the dielectric strength test voltages listed in Table 5B of UL 60950-1. In consideration of clause 5.2.2, care must be taken to insure the voltage applied to a reinforced insulation does not over stress basic insulation. Secondary to ground capacitors may need to be removed prior to performing a dielectric strength type test on the end product. It is highly recommended that the DC test voltages be used when performing a production-line dielectric strength test of the assembled end product. Please consult factory for further information.
 
  1. This power supply has been safety approved and final tested using a DC
    dielectric strength test. Please consult factory before performing AC dielectric strength test.
  2. Maximum screw penetration into mounting holes is .250 inches
 

 Maximum Output Power vs. Ambient Temperature

 
   CONNECTOR SPECIFICATIONS
TB1 AC Input .156 friction lock header mates with Molex 09-50-3051 or equivalent crimp terminal housing with Molex 08-50-0189 or equivalent crimp terminal.
TB2 DC Output .156 friction lock header mates with Molex 09-50-3101 or equivalent crimp terminal housing with Molex 08-50-0189 or equivalent crimp terminal.
PF Optional power fail signal.
      G          Optional power fail signal return.
   RECOMMENDED AIR FLOW DIRECTION
  1. Optimum
  2. Good
  3. Fair
   