70 WATTS

    NO MINIMUM ORDER REQUIRED

REL-70 SERIES

     

 OUTPUT SPECIFICATIONS  

Features

  • RoHS Compliant
  • Universal 85-264 VAC Input
  • Advanced SMT Design
  • Compact 2.5" X 4.5" X 1.2" Size
  • Class B Emissions Per EN 55011/22
  • EMC to EN 61000-6-2 & EN 60601-1-2
  • 2 Year Warranty
  • Fits 1U Application
  • One to Four Outputs
  • EN 60950-1 ITE Certification
  • EN 60601-1 Medical Certification
  • Optional Chassis & Cover
  • Harmonic Current per EN 61000-3-2
  • High Efficiency

Total Output Power 50W Convection Cooled
70W  Forced Air Cooled
Output Voltage Centering Output 1: +/-0.5%
Output 2,3,4: +/-5.0%
(All outputs at 50% load)
Source Regulation Outputs 1-4: 0.5%

 Load Regulation

 
Output 1:0.5% (10-100% Load Change)
Output 2: 5.0% (20-100% Load Change)
(4001-5) 8.0% (20-100% Load Change)
(2001) 8.0% (20-100% Load Change)
Output 3: 5.0% (20-100% Load Change)
Output 4: 5.0% (20-100% Load Change)
Cross Regulation Output 2-4: 5.0%
Output Voltage Adjust Range  Output 1: 95% to 105%
Output Noise Outputs 1-4: 1.0%
Turn On Overshoot None
Transient Response Outputs 1-4
Volt. Deviation 5.0%
Recovery Time 500 MicroS
Load Change 50% To 100%
Output Overvoltage Protection Output 1: 110% to 150%
Output Overpower Protection 110-160% rated Pout, cycle on/off, auto recovery
Hold Up Time 16 mS Min, Full Power
85 V Input
Start Up Time 4 Second, 120 V Input
   INPUT SPECIFICATIONS  
Source Voltage 85-264 Voltage AC
Frequency Range 47-63 Hz
Peak Inrush 40A
Efficiency .78% Typ., Full Power, 230V (Varies by model)
Power Factor 0.95(Full Power, 230V)
   ENVIRONMENTAL SPECIFICATIONS  
Ambient Operating Temperature Range 0oC to +70oC    Derating: See Power Rating Chart
Ambient Storage Temperature Range -40oC to +85oC
Temperature Coefficient Outputs 1-4: 0.02%/oC

  ELECTROMAGNETIC COMPATIBILITY
   GENERAL SPECIFICATIONS  
Electrostatic Discharge EN 61000-4-2 +/-8kV Contact Discharge
+/-8kVAir Discharge
Radiated Electro-magnetic Field EN 61000-4-3 80MHz-2.5GHz, 10V/m, 80% AM
EFT/Bursts EN 61000-4-4 +/-2kV
Surges EN 61000-4-5 +/-1 kV Common Mode
+/-2 kV Differential Mode
Conducted Immunity EN 61000-4-6 .15-80MHz., 10V, 80% AM
Voltage Dips and Interruptions EN 61000-4-11 30% Dip,500mS
95% Dip,10mS
60% Reduction,1s (Criteria B)
95% Reduction,5000ms
Radiated  Emissions EN55011/22 Class B
Conducted Emissions EN55011/22 Class B
Harmonic Current Emissions EN 61000-3-2  
Voltage Fluctuations and Flicker EN 61000-3-3  
Dielectric Strength  
Reinforced Insulation 5656 VDC, Primary to Secondary, 1 Sec.
Basic Insulation 2121 VDC, Primary to Ground, 1 Sec.

Operational Insulation

500 VDC, Secondary to Ground, 1 Sec.
Leakage Current <300 µA Earth Leakage Current
Power Fail Signal Logic low with input power failure 10mS minimum prior to output 1 dropping 1%
Remote Sense(singles only) 250mV compensation of output cable losses
Mean Time Between Failures 100,000 Hours min., MIL-HDBK-217F, 25oC, GB
Weight 1.00 Lbs.  Chassis and Cover
0.60 Lbs.  Open Frame
   Notes  
Consult factory for alternate output configuration.
Consult factory for positive, negative or floating output.
Refer to Application Information for complete output power ratings.

All specifications are maximum at 25C unless otherwise stated and are subjected to change without notice.
Specify optional chassis and cover when ordering.
   MODEL LISTING
Model Output 1 Output 2 Output 3 Output 4
REL-70-4001 +3.3V/6A +5V/5A +12V/2A(6) -12V/2A(6)
REL-70-4002 +5V/6A +3.3V/5A +12V/2A(6) -12V/2A(6)
REL-70-4003 +5V/6A +3.3V/5A +15V/2A(6) -15V/2A(6)
REL-70-4004 +5V/6A -5V/5A +12V/2A(6) -12V/2A(6)
REL-70-4005 +5V/6A -5V/5A +15V/2A(6) -15V/2A(6)
REL-70-4006 +5V/6A +24V/2A +12V/2A(6) -12V/2A(6)

REL-70-4007

REL-70-4009

+5V/6A

6.7V/5A

+24V/2A

5V/4A

+15V/2A(6)

+15V/2A

-15V/2A(6)

-15V/2A

REL-70-3001 +5V/6A +12V/2A   -12V/2A

REL-70-3002

REL-70-3003

REL-70-3004

+5V/6A

5.1V/6A

+3.3V/6A

+15V/2A

+7.5V/2A

+7V/5A

 

 

+12V/2A

-15V/2A

-7.5V/2A

 

REL-70-2001 +3.3V/6A +5V/5A    
REL-70-2002 +5V/6A +12V/4A    
REL-70-2003 +5V/6A +24V/2A    
REL-70-2004 +12V/3A -12V/3A    

REL-70-2005

REL-70-2006

+15V/3A

+5.5V/6A

-15V/2A

-5.5V/5A

 

 

 

 

REL-70-1001 2.5V/14A      
REL-70-1002 3.3V/14A      
REL-70-1003 5V/14A      
REL-70-1004 12V/5.8A      
REL-70-1005 15V/4.7A      
REL-70-1006 24V/2.9A      
REL-70-1007 28V/2.5A      
REL-70-1008 48V/1.5A      
   SAFETY SPECIFICATIONS  
General   Protection Class:

I

Overvoltage Category:

II

Pollution Degree:

2

 

Underwriters
Laboratories
File E137708

     

UL 60950-1 First Edition
UL 60601-1 First Edition


CB Report Per IEC 60950-1(2001)                                    First Edition
All National Deviations
CB Report Per IEC 60601-1(1988)
Second Edition, A1, A2

 
UL Recognition Mark for Canada
File E137708
CAN/CSA-C22.2 No. 60950-1-03
CAN/CSA-C22.2 No. 601-1-M90                                       with updates 1 and 2
 
TUV EN 60950-1:2001
EN 60601-1/A2: 1995
 
  Low Voltage Directive  
   REL-70 SERIES MECHANICAL SPECIFICATIONS  

   APPLICATIONS INFORMATION
  1. Rated 10A with convection cooling.
  2. Total power must not exceed 50 watts with convection cooling on open frame models.
  3. Total power must not exceed 70 watts with 300LFM forced air cooling on open frame models.
  4. Total power must not exceed 40 watts with convection cooling and chassis/cover option.
  5. Total power must not exceed 70 watts with 300LFM forced air cooling and chassis/cover option.
  6. Each output can deliver its rated current but total output power must not exceed maximum power as determined by the cooling method state above.
  7. Rated 1.5 A with convection cooling.
  8. Sufficient area must be provided around convection cooled power supplies to allow natural movement of air develop.
  9. 300 linear feet per minute of airflow must be maintained one inch above any point of the heatsink in the direction shown when forced air cooling is required.
  10. A minimum load of 10% is required on output one to insure proper regulation of remaining outputs.
  11. Peak to peak output ripple and noise is measured directly at the output
    terminals of the power supply, without the use of the probe ground lead or retractable tip, 20 MHz bandwidth.
  12. This product was type tested and safety certificated using the the dielectric strength test voltages listed in Table V of UL 60601-1. In consideration of clause 20.4g, care must be taken to insure the voltage applied to a reinforced insulation does not over stress basic insulation. Secondary to ground capacitors may need to be removed prior to performing a dielectric strength type test on the end product. It is highly recommended that the DC test voltages listed in DVB.1. Annex DVB are not exceeded during a production-line dielectric strength test of the assembled end product. Please consult factory for further information.
 
  1. This product is intended for use as a professionally installed component within information technology and medical equipment.
  2. Remote sense terminals may be used to compensate for cable losses up to 250mV. The use of a twisted pair is recommended as well as a decoupling capacitor (0.1 0 10µF) and a capacitor of 100µF/amp connected across the load.
  3. This power supply has been safety approved and final tested using a DC
    dielectric strength test. Please consult factory before performing AC dielectric strength test.
  4. Maximum screw penetration into bottom chassis mounting holes is .100 inches.
  5. Maximum screw penetration into side chassis mounting holes is .250 inches.
  6. To meet emissions specifications, all four mounting hole ground pads must
    be electrically connected to a common metal chassis. Chassis/cover option recommended.
  7. This product is use only one fuse in the input circuit. In consideration of clause 57.6 of UL 60601-1, a second fuse may be required in the end product.
 

 Maximum Output Power vs. Ambient Temperature

   CONNECTOR SPECIFICATIONS
P1 AC Input .156 friction lock header mates with Molex 09-50-3031 or equivalent crimp terminal housing with Molex 2478 or equivalent crimp terminal.
P2 DC Output(Single) .156 friction lock header mates with Molex 09-50-3081 or equivalent crimp terminal housing with Molex 2478 or equivalent crimp terminal.
P2 DC Output(Multiple) .156 friction lock header mates with Molex 09-50-3081 or equivalent crimp terminal housing with Molex 2478 or equivalent crimp terminal.
G Ground .187 quick disconnect terminal.
P3 P.F./Sense(Single) .100 breakaway header mates with Molex 22-55-2061 or equivalent crimp terminal housing with Molex type 71851 or equivalent crimp terminal.
P3 Power Fail (Multiple)  .100 breakaway header mates with Molex 50-57-9002 or equivalent crimp terminal housing with Molex type 71851 or equivalent crimp terminal.
   RECOMMENDED AIR FLOW DIRECTION
  1.Optimum  2.Good  3.Fair
   