100 WATTS |
NO MINIMUM ORDER REQUIRED |
|
SRW-100 SERIES |
|
Features
- RoHS Compliant
- Universal 85-264 VAC Input
- Compact 3.3" X 5" X 1.5" Size
- EMC to EN 61000-6-2 & EN 60601-1-2
- 2 Year Warranty
- One to Four Tightly Regulated Outputs
- EN 60950 ITE Certification
- EN 60601-1 Medical Certification
- Optional Perforated Cover

|
| Total Output Power at 50o C |
70W Convection Cooled |
| 85W Convection Cooled w/1 Sq.ft. baseplate |
| 100W LFM Forced Air |
| Output Voltage Centering |
Output 1: +/-0.25% Output 2:(SRW) +/-0.25% (SRP) +/-5.0% Output 3: +/-2.0% Output 4: +/-2.0% (All outputs at 50% load) |
| Source Regulation |
Outputs 1-4: 0.5% |
| Load Regulation |
Output 1:0.5% (10-100% Load Change) |
| Output 2: |
(SRW) 0.5% (10-100% Load Change) |
| (SRP) 5.0% (10-100% Load Change) |
| Output 3: 1.0% (10-100% Load Change) |
| Output 4: 1.0% (10-100% Load Change) |
| Cross Regulation |
Output 2: |
(SRW) 0.2% |
|
| (SRP) 5.0% |
| Output 3: 0.2% |
|
Output 4: 0.2% (Output 1 load varied 50-100%) |
| Output Voltage Adjust Range |
Output 1: 95-105% 85-105%(1001,4001) Output 2: 95-105% (SRW models only) |
| Output Noise |
Outputs 1-4: 1.0% |
| Turn On Overshoot |
None |
| Transient Response |
Outputs 1-4 Voltage Deviation 5.0% Recovery Time 2mS Load Change 50% to 100% |
| Output Overvoltage Protection (Optional) |
Output 1: 110% to 150% |
| Output Overpower Protection |
Outputs 1 & 2: 110% Min Outputs cycle on/off, auto recovery |
| Output Overcurrent Protection |
Outputs 3 & 4: 110% Min |
| Hold Up Time |
10 mS min., 100W, 120V Input |
| Start Up Time |
1 Second | |
| Dielectric Strength |
|
| Reinforced Insulation |
5656 VDC, Primary to Secondary, 1 Sec. |
| Basic Insulation |
2121 VDC, Primary to Ground, 1 Sec. |
| Operational Insulation |
707 VDC, Secondary to Ground, 1 Sec. |
| Leakage Current |
<500 µA Earth Leakage Current |
Power Fail Signal (optional) |
Logic low with input power failure 2mS minimum prior to output 1 dropping 1% |
| Remote Sense (single output models only) |
250mV compensation of output cable losses |
| Mean Time Between Failures |
150,000 Hours min., MIL-HDBK-217F, 25oC, GB |
| Weight |
1.00 Lbs. Chassis 1.05 Lbs. Chassis/Cover | |
| Source Voltage |
85-264 Volts AC |
| Frequency Range |
47-63 Hz |
Source Current True RMS Peak Inrush |
3A at 85V Input 30A |
| Efficiency |
.68-.84 (Varies by model) | |
| |
ENVIRONMENTAL SPECIFICATIONS |
|
| Ambient Operating Temperature Range |
0oC to +70oC Derating: See Power Rating Chart |
| Ambient Storage Temp. Range |
-40oC to +85oC |
| Temperature Coefficient |
Outputs 1-4: 0.02%/oC | |
| |
ELECTROMAGNETIC COMPATIBILITY | |
| Electrostatic Discharge |
EN 61000-4-2 |
+/-8kV Contact Discharge +/-8kV Air Discharge |
| Radiated Electromagnetic Field |
EN 61000-4-3 |
80MHz-2.5GHz, 10V/m, 80% AM |
| EFT/Bursts |
EN 61000-4-4 |
+/-2kV |
| Surges |
EN 61000-4-5 |
+/-1 kV Differential Mode +/-2 kV Common Mode |
| Conducted Immunity |
EN 61000-4-6 |
.15-80MHz., 10V, 80% AM |
| Voltage Dips and Interruptions |
EN 61000-4-11 |
30% Reduction,500mS |
| 95% Reduction,10mS |
| 60% Reduction, 1s (Criteria B) |
| 95% Reduction,5000ms |
| Radiated Emissions |
EN 55011/22 |
Class A |
| Conducted Emissions |
EN 55011/22 |
Class B |
|
|
|
|
|
| |
| Model NO. |
Output 1 |
Output 2 |
Output 3 |
Output 4 |
| SRW-100-4001 |
+3.3V/10A(2) |
+5V/4A |
+12V/2A(3) |
-12V/1A |
| SRW-100-4002 |
+5V/10A(2) |
+24V/2A |
+12V/2A(3) |
-12V/1A |
| SRW-100-4003 |
+5V/10A(2) |
+24V/2A |
+15V/2A(3) |
-15V/1A |
| SRW-100-4004 |
+5V/10A(2) |
-5.2V/4A |
+12V/2A(3) |
-12V/1A |
| SRW-100-4005 |
+5V/10A(2) |
-5.2V/4A |
+15V/2A(3) |
-15V/1A |
| SRW-100-4006 |
+5V/10A(2) |
+3.4V/4A |
+9V/1A |
24V/0.5A |
| SRW-100-4007 |
+5V/10A(2) |
+15V/3A |
+12V/2A(3) |
-12V/1A |
| SRW-100-4008 |
+5V/10A(2) |
3.3V/4A |
+12V/2A(3) |
-5V/1A |
| SRW-100-4009-IT |
+3.3V/10A(2) |
+5V/4A |
+12V/2A(3) |
-5V/1A |
| SRW-100-4010 |
+5V/5A |
+15V/4A |
+12V/2A(3) |
9V/2.5A |
| SRW-100-4011 |
+5V/10A(2) |
-15V/2.2A |
+15V/2.2A(3) |
12V/1A |
| SRW-100-4012 |
+5V/10A(2) |
3.3V/4A |
+12V/2A(3) |
-12V/1A |
| SRW-100-3001 |
+5V/10A(2) |
+12V/4A |
|
-12V/1A |
| SRW-100-3002 |
+5V/10A(2) |
+15V/3A |
|
-15V/1A |
| SRW-100-3003 |
+5V/10A(2) |
+3.3V/8A |
|
12V/1A |
| SRW-100-3004 |
+3.3V/5A |
+5.8V/3A |
|
-48V/1A |
| SRW-100-2001 |
+12V/5A |
-12V/4A |
|
|
| SRW-100-2002 |
+15V/5A |
-15V/3A |
|
|
| SRW-100-2003 |
+12.5V/4A |
+16V/2A |
|
|
| SRW-100-1001 |
3.3V/20A(4) |
|
|
|
| SRW-100-1002 |
5V/20A |
|
|
|
| SRW-100-1003 |
12V/8.3A |
|
|
|
| SRW-100-1004 |
15V/6.7A |
|
|
|
| SRW-100-1005 |
24V/4.2A |
|
|
|
| SRW-100-1006 |
28V/3.6A |
|
|
|
| SRW-100-1007 |
48V/2.1A |
|
|
|
| SRW-100-1008 |
40V/2.5A |
|
|
|
| SRP-100-4001 |
+5V/12A(2) |
+24V/3A |
+12V/2A(3) |
-12V/1A |
| SRP-100-4002 |
+5V/12A(2) |
+24V/3A |
+15V/2A(3) |
-15V/1A |
| SPR-100-4003 |
+5V/12A(2) |
-5V/4A |
+12V/2A(3) |
-12V/1A |
| SRP-100-4004 |
+5V/12A(2) |
-5V/4A |
+15V/2A(3) |
-15V/1A |
| SRP-100-4005 |
+5V/12A |
+12V/3A |
+8V/2A |
-8V/1A |
| SRP-100-3001 |
+5V/12A(2) |
+12V/4A |
|
-12V/1A |
| SRP-100-2001 |
+5V/12A(2) |
+24V/3A |
|
| |
|
|
|
Consult factory for alternate output configurations. Consult factory for positive, negative or floating outputs.
Refer to Application Information for complete output power ratings. All specifications are maximum at 25o C unless otherwise stated and are subjected to change without notice.
Specify optional perforated cover, power fail, overvoltage protection, isolated output 2, isolated output 4 or DC Input when ordering. |
| General |
|
Protection Class: |
I |
| Overvoltage Category: |
II |
| Pollution Degree: |
2 |
|


|
Underwriters Laboratories File E137708 |
UL 60950-1 First Edition UL 60601-1 First Edition
CB Report Per IEC 60950-1(2001) First Edition All National Deviations CB Report Per IEC 60601-1-(1988) First Edition, A1, A2
|
|
 |
UL Recognition Mark for Canada File E137708 |
CAN/CSA-C22.2 No. 60950-1-03 CAN/CSA-C22.2 No. 601-1-M90 with updates 1 and 2 |
|
 |
TUV |
EN 60950-1:2001 EN 60601-1/A2: 1995 |
|
 |
|
Low Voltage Directive |
| |
| |
SRW/SRP-100 SERIES MECHANICAL SPECIFICATIONS |
|  |
|




|
|
|
- Each output can deliver its rated current but total output power must not exceed 70, 85 or 100 watts as determined by cooling method.
- Rated 8A maximum when convection cooled only.
- Rated 1A maximum when convection cooled only.
- Rated 50 watts maximum output power when convection cooled, 70 watts when baseplate or forced air cooled.
- Free air convection cooling, 70 watts maximum output power.
- Base plate cooling rating of 85 watts requires a one square foot.09 thick aluminium area attached to bottom four mounting holes.
- Forced air cooling rating of 100 watts requires an air speed of 200 linear feet per minute flowing past a point one inch above the main isolation transformer.
- Semiconductor case temperatures must not exceed 110o C.
- Sufficient area must be provided around the convection cooled power supplies to allow natural movement of air to develop.
- This product is intended for use as professionally installed component within information technology and medical equipment.
- A minimum load of 10% is required on output one to ensure proper regulation of remaining outputs.
- Remote sense terminals may be used to compensate for cable losses up to 250mV. The use of twisted pair is recommended as well as a decoupling capacitor (0.1-10µF) and a capacitor of 100µF /amp connected across the load side.
- Peak to peak output ripple and noise is measured directly at the output
terminals of the power supply, without the use of the probe ground lead or retractable tip, 20 MHz bandwidth.
- This product includes only one fuse in the input circuit. In consideration of Clause 57.6 of UL 60601-1, a second fuse may be required in the
end product.
- This power supply has been safety approved and final tested using a DC dielectric strength test. Please consult factory before performing an AC dielectric strength test.
- Maximum screw penetration into chassis mounting holes is .125 inches.
|
| |
RECOMMENDED AIR FLOW DIRECTION |
| 1.Optimum 2.Good 3.Fair | | |
| |
- This product was type tested and safety
certificated using the the dielectric strength test voltages listed in Table V of UL 60601-1. In consideration of clause 20.4g, care must be taken to insure the voltage applied to a reinforced insulation does not over stress basic insulation. Secondary to ground capacitors may need to be removed prior to performing a dielectric strength type test on the end product. It is highly recommended that the DC test voltages listed in DVB.1. Annex DVB are not exceeded during a production-line dielectric strength test of the assembled end product. Please consult factory for further information. |
| |
Maximum Output Power vs. Ambient Temperature | |
 |
| P1 |
AC Input (Single) |
Terminal block with 4-40 screws on 0.325 inch centers mates with #4 spade terminals. |
| P1 |
AC Input (Multiple) |
.156 friction lock header mates with Molex 09-50-3031 or equivalent crimp terminal housing with Molex 08-50-0189 or equivalent crimp terminal. |
| P2 |
DC Output(Single) |
6-32 screw down terminal mates with #6 ring tongue terminal.(10 in-lb max.) |
| P2 |
DC Output(Multiple) |
.156 friction lock header mates with Molex 09-50-3101 or equivalent crimp terminal housing with Molex 08-50-0189 or equivalent crimp terminal. |
| G |
Ground |
.187 quick disconnect terminal. |
| P3 |
Option/Sense(Single) |
.100 friction lock header mates with Molex 22-01-2047 or equivalent crimp terminal housing with Molex 6459 or equivalent crimp terminal. |
| P3 |
Option(Multiple) |
.100 friction lock header mates with Molex 22-01-2027 or equivalent crimp terminal housing with Molex 6459 or equivalent crimp terminal. | |
| | | |