185 WATTS |
NO MINIMUM ORDER REQUIRED |
|
REL-185 SERIES |
|
Features
- RoHS Compliant
- Advanced SMT Design
- Compact 4.2" X 7.0" X 1.5" Size
- 2 Year Warranty
- Fits 1U Application
- One to Four Outputs
- EN 60950-1 ITE Certification
- EN 60601-1 Medical Certification
- Harmonic Current per EN 61000-3-2
- Class B Emissions Per EN 55011/22
- EMC to EN 61000-6-2 & EN 60601-1-2
- Optional Chassis & Cover
- Universal 85-264 VAC Input
- High Efficiency

|
| Total Output Power at 50c |
135W Convection Cooled |
| 185W 300 LMF Forced Air |
| Output Voltage Centering |
Output 1: +/-0.5% Output 2: +/-5.0% Output 3: +/-5.0% Output 4: +/-5.0% (All outputs at 50% load) |
| Source Regulation |
Outputs 1-4: 0.5% |
| Load Regulation |
Output 1:0.5% (10-100% Load Change) |
| Output 2: 5.0% (10-100% Load Change) |
| (4001,4,5,2001) 10.0% (20-100% Load Change) |
| (4002,4003) 15.0% (20-100% Load Change) |
| Output 3: 5.0% (10-100% Load Change) |
| Output 4: 5.0% (10-100% Load Change) |
| Cross Regulation |
Output 2-4: 6.0% |
| Output Voltage Adjust Range |
Output 1: 95%-105% |
| Output Noise |
Outputs 1-4: 1.0% |
| Turn On Overshoot |
None |
| Transient Response |
Outputs 1-4: |
| Voltage Deviation |
5.0% |
| Recovery Time |
500 MicroS |
| Load Change |
50% To 100% |
| Output Overvoltage Protection |
Output 1: 110% to 150% |
| Output Overpower Protection |
110-160% rated Pout, cycle on/off, auto recovery |
| Hold Up Time |
16 mS Min, Full Power 85 V Input |
| Start Up Time |
5 Second, 120V Input | |
| Source Voltage |
85-264 Voltage AC |
| Frequency Range |
47-63 Hz |
| Peak Inrush Current |
40A |
| Efficiency |
.82% Typ., Full Power, 230V (Varies by model) |
| Power Factor |
0.95(Full Power, 230V) | |
| |
ENVIRONMENTAL SPECIFICATIONS |
|
| Ambient Operating Temperature Range |
0oC to +70oC Derating: See Power Rating Chart |
| Ambient Storage Temp. Range |
-40oC to +85oC |
| Temperature Coefficient |
Outputs 1-4: 0.02%/oC | |
| |
ELECTROMAGNETIC COMPATIBILITY | |
|
| Electrostatic Discharge |
EN 61000-4-2 |
+/-8kV Contact Discharge +/-8kVAir Discharge |
| Radiated Electro-magnetic Field |
EN 61000-4-3 |
80MHz-2.5GHz, 10V/m, 80% AM |
| EFT/Bursts |
EN 61000-4-4 |
+/-2kV |
| Surges |
EN 61000-4-5 |
+/-1 kV Common Mode +/-2 kV Differential Mode |
| Conducted Immunity |
EN 61000-4-6 |
.15-80MHz., 10V, 80% AM |
| Voltage Dips and Interruptions |
EN 61000-4-11 |
30% Dip,500ms |
| 95% Dip,10ms |
| 60% Reduction,1s (Criteria B) |
| 95% Reduction,5000ms |
| Radiated Emissions |
EN55011/22 |
Class B |
| Conducted Emissions |
EN55011/22 |
Class B |
| Harmonic Current Emissions |
EN 61000-3-2 |
|
| Voltage Fluctuations and Flicker |
EN 61000-3-3 |
| |
| Dielectric Strength |
|
| Reinforced Insulation |
5656 VDC, Primary to Secondary, 1 Sec. |
| Basic Insulation |
2121 VDC, Primary to Ground, 1 Sec. |
|
Operational Insulation |
707 VDC, Secondary to Ground, 1 Sec. |
| Leakage Current |
<300 µA Earth Leakage Current |
|
Power Fail Signal
Remote on/off (optional) |
Logic low with input power failure 10mS minimum prior to output 1 dropping 1%
Contact closure shuts off all outputs |
| Remote Sense |
250mV compensation of output cable losses |
| Mean Time Between Failures |
100,000 Hours min., MIL-HDBK-217F, 25oC, GB |
| Weight |
1.70 Lbs. Open Frame 2.70 Lbs. Chassis and Cover | |
| Model |
Output 1 |
Output 2 |
Output 3 |
Output 4 |
| REL-185-4001 |
+3.3V/20A(1) |
+5V/10A |
+12V/2A |
-12V/2A |
| REL-185-4002 |
+5V/20A(1) |
+3.3V/10A |
+12V/2A |
-12V/2A |
| REL-185-4003 |
+5V/20A(1) |
+3.3V/10A |
+15V/2A |
-15V/2A |
| REL-185-4004 |
+5V/20A(1) |
-5V/10A |
+12V/2A |
-12V/2A |
| REL-185-4005 |
+5V/20A(1) |
-5V/10A |
+15V/2A |
-15V/2A |
| REL-185-4006 |
+5V/20A(1) |
+24V/3A |
+12V/2A |
-12V/2A |
| REL-185-4007 |
+5V/20A(1) |
+24V/3A |
+15V/2A |
-15V/2A |
| REL-185-3001 |
+5V/20A(1) |
+12V/5A |
|
-12V/3A |
| REL-185-3002 |
+5V/20A(1) |
+15V/4A |
|
-15V/3A |
| REL-185-2001 |
+3.3V/20A(1) |
+5V/10A |
|
|
| REL-185-2002 |
+5V/20A(1) |
+12V/8A |
|
|
| REL-185-2003 |
+5V/20A(1) |
+24V/4A |
|
|
| REL-185-2004 |
+12V/10A |
-12V/6A |
|
|
| REL-185-2005 |
+15V/8A |
-15V/5A |
|
|
| REL-185-2006 |
+15V/6A |
+24V/4A |
|
|
| REL-185-2007 |
+35V/3.5A |
+12V/5.2A |
|
|
| REL-185-1001 |
2.5V/37A(2) |
|
|
|
| REL-185-1002 |
3.3V/37A(2) |
|
|
|
| REL-185-1003 |
5V/37A(2) |
|
|
|
| REL-185-1004 |
12V/15.4A |
|
|
|
| REL-185-1005 |
15V/12.3A |
|
|
|
| REL-185-1006 |
24V/7.7A |
|
|
|
| REL-185-1007 |
28V/6.6A |
|
|
|
| REL-185-1008 |
48V/3.8A |
|
|
|
| REL-185-1009 |
6.3V/29A(2) |
|
|
| |
Consult factory for alternate output configuration. Consult factory for positive, negative or floating outputs. Refer to Application Information for complete output power ratings. All specifications are maximum at 25oC unless otherwise stated and are subjected to change without notice. Specify optional chassis and cover or remote when ordering. |
| General |
|
Protection Class: |
I |
| Overvoltage Category: |
II |
| Pollution Degree: |
2 |
|


|
Underwriters Laboratories File E137708 |
UL 60950-1 First Edition UL 60601-1 First Edition
CB Report per IEC 60950-1(2001) First Edition All National Deviations CB Report Per IEC 60601-1(1988) First Edition, A1, A2
|
|
 |
UL Recognition Mark for Canada File E137708 |
CAN/CSA-C22.2 No. 60950-1-03 CAN/CSA-C22.2 No. 601-1-M90 with updates 1 and 2 |
|
 |
TUV |
EN 60950-1:2001 EN 60601-1/A2: 1995 |
|
 |
|
Low Voltage Directive |
| |
| |
REL-185 SERIES MECHANICAL SPECIFICATIONS |
| |
|






|
|
|
- Rated 15A with convection cooling.
- Rated 27A with convection cooling.
- Total power must not exceed 135 watts with convection cooling on open frame models except where noted.
- Total power must not exceed 185 watts with 300 LFM forced air cooling on open frame models.
- Total power must not exceed 110 watts with with convection cooling and chassis/cover option.
- Total power must not exceed 185 watts with 300 LMF forced air cooling and chassis/cover option.
- Total current from Outputs 3 & 4 must not exceed 3 amps with convection cooling.
- Total current from Outputs 1 & 2 must not exceed 20 amps with convection cooling.
- Semiconductor case temperature must not exceed 110o C.
- Each output can deliver its rated current but total output power must not exceed maximum power as determined by the cooling method state above.
- Sufficient area must be provided around convection cooled power supplies to allow natural movement of air develop.
- 300 linear feet per minute of airflow must be maintained one inch above any point of the heatsink in the direction shown when forced air cooling is required.
- This product is intended for use as a professionally installed component within information technology and medical equipment.
- A minimum load of 10% is required on output one to insure proper regulation of remaining outputs.
- Remote sense terminals may be used to compensate for cable losses up to 250mV. The use of a twisted pair is recommended as well as a decoupling capacitor (0.1 0 10µF) and a capacitor of 100µF/amp connected across the load.
- Peak to peak output ripple and noise is measured directly at the output
terminals of the power supply, without the use of the probe ground lead or retractable tip, 20 MHz bandwidth. | |
| |
- This product was type tested and safety certificated using the the dielectric strength test voltages listed in Table V of UL 60601-1. In consideration of clause 20.4g, care must be taken to insure the voltage applied to a reinforced insulation does not over stress basic insulation. Secondary to ground capacitors may need to be removed prior to performing a dielectric strength type test on the end product. It is highly recommended that the DC test voltages listed in DVB.1. Annex DVB are not exceeded during a production-line dielectric strength test of the assembled end product. Please consult factory for further information.
- This power supply has been safety approved and final tested using a DC
dielectric strength test. Please consult factory before performing AC dielectric strength test.
- Maximum screw penetration into bottom chassis mounting holes is .100 inches.
- Maximum screw penetration into side chassis mounting holes is .250 inches.
- To meet emissions specifications, all four mounting hole ground pads must
be electrically connected to a common metal chassis. Chassis/cover option recommended.
- This product is use only one fuse in the input circuit. In consideration of clause 57.6 of UL 60601-1, a second fuse may be required in the end product.
|
| |
Maximum Output Power vs. Ambient Temperature | |
 | |
| P1 |
AC Input |
.156 friction lock header mates with Molex 09-50-3031 or equivalent crimp terminal housing with Molex 2478 or equivalent crimp terminal. |
| P2 |
DC Output (Single) |
6-32 screw down terminal mates with #6 ring tongue terminal.(10 in-lb max) |
| P2 |
DC Output (Multiple) |
.156 friction lock header mates with Molex 09-50-3161 or equivalent crimp terminal housing with Molex 2478 or equivalent crimp terminal. |
| G |
Ground |
.187 quick disconnect terminal. |
| P3 |
Option/Sense(Single) |
.100 friction lock header mates with Molex 50-57-9008 or equivalent crimp terminal housing with Molex type 71851 or equivalent crimp terminal. |
| P3 |
Option/Sense(Multiple) |
.100 breakaway header mates with Molex 22-55-2081 or equivalent crimp terminal housing with Molex type 71851 or equivalent crimp terminal. |
| |
RECOMMENDED AIR FLOW DIRECTION |
| 1.Optimum 2.Good 3.Fair | | |