225 WATTS

  NO MINIMUM ORDERS REQUIRED

CE-225 SERIES

     

 OUTPUT SPECIFICATIONS  
Features
  • RoHS Compliant
  • Universal 85-264 VAC Input  
  • Compact 4.75" X 8.0" X 2.0" Size
  • 2 Year Warranty
  • One to Four Tightly Regulated Outputs 
  • EN 60950-1 ITE Certification
  • EN 60601-1 Medical Certification
  • Class B Emissions Per EN 55011/22
  • Harmonic Current per EN 61000-3-2
  • EMC to EN 61000-6-2 & EN 60601-1-2
  • Optional Perforated Cover

Total Output Power at 50C  150W Convection cooled
225W  300 LFM Forced Air
Output Voltage Centering Output 1:  +/-0.25%
Output 2:  +/-0.25%  (X0XX)
               +/-5.0% (X1XX)
Output 3:  +/-2.0%
Output 4:  +/-2.0%
(All outputs at 50% load)
Source Regulation Outputs 1-4: 0.5%
Load Regulation
Output 1:0.5%              (10-100% Load Change)
Output 2:
(X0XX) 0.5%                   (0-100% Load Change)
(X1XX) 5.0%                  (10-100% Load Change)
Output 3: 2.0%               (0-100% Load Change)
Output 4: 2.0%              (0-100% Load Change)
Cross Regulation Output 2:   0.2%(X0XX)
                5.0%(X1XX)
Output 3:   2.0%
Output 4:   2.0%
(Output 1 load varied 50-100%)
Output Voltage Adjust Range Output1-2:95%-105%(X0XX)
Output 1: 95%-105% (X1XX)
Output 1: 85%-105% (1001,4001)
Output 2: 85%-105% (4002,4003)
Output Noise Outputs 1-4: 1.0%
 Turn On Overshoot  None
Transient Response Outputs 1-4:
Volt. Deviation 5.0%
Recovery Time 500 MicroS
Load Change 50% To 100%
Output Overvoltage Protection (Optional) Output 1: 110% to 150%.Shuts down all
outputs.Cycle
input to restart
Output Overpower Protection 250 W Min., Outputs 1 
Outputs cycle on/off, auto recovery
Output Overcurrent Protection 110% Min., Outputs 2,3 & 4
Hold Up Time 20 mS Min, 225 W Output
120 V Inputt
Start Up Time 3 Seconds
   INPUT SPECIFICATIONS  
Source Voltage 85-264 Voltage AC
Frequency Range 47-63 Hz
Source Current  
True RMS 4.25A At 85V Inputut
Peak Inrush 30A
Peak Repetitive 6.0A at 85V Input
Harmonic Distortion 0.05
Efficiency .68 -.80 (Varies by model)
Power Factor 0.92 (225 watts, 230V)
   ENVIRONMENTAL SPECIFICATIONS  
Ambient Operating Temperature Range 0oC to +70oC       Derating: See Power Rating Chart
Ambient Storage Temperature Range -40oC to +85oC
Temperature Coefficient Outputs 1-4: 0.02%/oC

   SAFETY SPECIFICATIONS  
   GENERAL SPECIFICATIONS  
General   Protection Class:

I

Overvoltage Category:

II

Pollution Degree:

2

 

 

Underwriters
Laboratories
File E137708

UL 60950-1 First Edition             UL 60601-1            First Edition  

CB Report Per IEC 60950-1(2001)      First Edition             All National Deviations CB Report Per IEC 60601-1(1988)       First Edition, A1, A2

 
UL Recognition Mark for Canada
File E137708
CAN/CSA-C22.2 No. 60950-1-03
CAN/CSA-C22.2 No. 601-1-M90             with updates 1 and 2
 
TUV EN 60950-1:2001
EN 60601-1/A2:1995
 
  Low Voltage Directive  
Dielectric Strength  

Reinforced Insulation

5656 VDC, Primary to Secondary, 1 Sec.

Basic Insulation

2121 VDC, Primary to Ground, 1 Sec.

Operational Insulation

707 VDC, Secondary to Ground, 1 Sec.
Leakage Current <300µA Earth Leakage Current
Power Fail Signal
(Optional)
Logic low with input power failure 10 mS minimum prior to output 1 dropping 1%
Remote On/Off (Optional) Contact closure shuts off all outputs
Remote Sense 250mV compensation of output cable losses
Mean-Time Between Failures 100,000 Hours min., MIL-HDBK-217F, 25o C, GB
Weight 3.00 Lbs. 
   MODEL LISTING
Model Output 1 Output 2 Output 3 Output 4
CE-225-4001 +3.3V/25A(1) +5V/8A(1) +12V/2A(1) -12V/2A(1)
CE-225-4002 +5V/25A(1) +3.3V/8A(1) +12V/2A -12V/2A
CE-225-4003 +5V/25A(1) +3.3V/8A(1) +15V/2A -15V/2A
CE-225-4004 +5V/25A(1) -5.2V/8A(1) +12V/2A -12V/2A
CE-225-4005 +5V/25A(1) -5.2V/8A(1) +15V/2A -15V/2A
CE-225-4006 +5V/25A(1) +12V/8A(1) +12V/2A -12V/2A
CE-225-4007 +5V/25A(1) +12V/8A(1) +15V/2A -15V/2A
CE-225-4008 +5V/25A(1) +12V/8A(1) +9V/2A -9V/2A
CE-225-4101 +5V/25A(1) +24V/8A(1) +12V/2A -12V/2A
CE-225-4102 +5V/25A(1) +24V/8A(1) +15V/2A -15V/2A
CE-225-4104 +24V/6A(1) +24V/3A(1) +12V/2A 5V/2A
CE-225-3001 +5V/25A(1) +12V/8A(1)   -12V/2A
CE-225-3002 +5V/25A(1) +15V/8A(1)   -15V/2A
CE-225-2001 +12V/10A(1) -12V/8A(1)    
CE-225-2002 +15V/10A -15V/8A(1)    
CE-225-2003 +5V/25A(1) +12V/8A    
CE-225-2004 +5.2V/30A -9V/6A    
CE-225-2005 +3.3V/25A +12V/8A    
CE-225-2101 +5V/25A(1) +24V/8A(1)    
CE-225-1001 3.3V/45A(6)      
CE-225-1002 5V/45A(6)      
CE-225-1003 12V/18.8A(1)      
CE-225-1004 15V/15A(1)      
CE-225-1005 24V/9.4A(1)      
CE-225-1006 28V/8A(1)      
CE-225-1007 48V/4.7A(1)      
CE-225-1008 48V/4.7A(1)      
CE-225-1009 39V/5.8A(1)      

   
ELECTROMAGNETIC COMPATIBILITY
Electrostatic Discharge EN 61000-4-2 +/-8kV Contact Discharge
+/-8kV Air Discharge
Radiated Electromagnetic Field EN 61000-4-3 80MHz-2.5GHz, 10V/m, 80% AM
EFT/Bursts EN 61000-4-4 +/-2kV
Surges EN 61000-4-5 +/-1 kV Differential Mode
+/-2 kV Common Mode
Conducted Immunity EN 61000-4-6 .15-80MHz., 10V, 80% AM
Voltage Dips and Interruptions EN 61000-4-11 30% Reduction,500mS
95% Reduction,10mS
60% Reduction, 1s (Criteria B)
95% Reduction,5000ms
Radiated Emissions EN 55011/22 Class B
Conducted Emissions EN 55011/22 Class B
Haromonic Current Emissions EN 61000-3-2  
                                     

   Notes
  Consult factory for alternate output configuration.
Consult factory for positive, negative or floating outputs.
Refer to Application Information for complete output power ratings.
All specifications are maximum at 25o C unless otherwise stated and are subjected to change without notice.
Specify optional perforated cover, power fail, overvoltage protection or remote on/off when ordering.
   CE-225 SERIES MECHANICAL SPECIFICATIONS  

   APPLICATIONS INFORMATION
  1. Derated 20% when convection cooled.
  2. Each output can deliver its rated current but total output power must not exceed 150 or 225 watts as determined by the cooling method.
  3. Rated 30 amps maximum when convection cooling only. 
  4. Free air convection cooling, 150 watts maximum output power.
  5. Forced air cooling rating of 225 watts requires an air speed of 300 linear feet per minute flowing past a point one inch above the main isolation transformer.
  6. Semiconductor case temperature must not exceed 110oC.
  7. Sufficient area must be provided around convection cooled power supplies to allow natural movement of air develop.
  8. 300 linear feet per minute of airflow must be maintained one inch above any point of the heatsink in the direction shown when forced air cooling is required.
  9. This product is intended for use as a professionally installed component within information technology and medical equipment.
  10. A minimum load of 10% is required on output one to insure proper regulation of remaining outputs.
  11. Remote sense terminals may be used to compensate for cable losses up to 250mV. The use of a twisted pair is recommended as well as a decoupling capacitor (0.1 0 10µF) and a capacitor of 100µF/amp connected across the load.
  12. Peak to peak output ripple and noise is measured directly at the output
    terminals of the power supply, without the use of the probe ground lead or retractable tip, 20 MHz bandwidth.
  13. This product includes only one fuse in the input circuit. In consideration of Clause 57.6 of UL 2601-1, a second fuse may be required in the end product.
  14. This product was type tested and safety certificated using the the dielectric strength test voltages listed in Table V of UL 60601-1. In consideration of clause 20.4g, care must be taken to insure the voltage applied to a reinforced insulation does not over stress basic insulation. Secondary to ground capacitors may need to be removed prior to performing a dielectric strength type test on the end product. It is highly recommended that the DC test voltages listed in DVB.1. Annex DVB are not exceeded during a production-line dielectric strength test of the assembled end product. Please consult factory for further information.
 
  1. This power supply has been safety approved and final tested using a DC dielectric strength test. Please consult factory before performing AC dielectric strength test.
  2. Maximum screw penetration into bottom chassis mounting holes is .187 inches.
 

 Maximum Output Power vs. Ambient Temperature

 
   CONNECTOR SPECIFICATIONS
P1 AC Input .156 friction lock header mates with Molex 09-50-3031 or equivalent crimp terminal housing with Molex 08-50-0189 or equivalent crimp terminal.
P2 DC Output(Single) 6-32 screw down terminal mates with #6 ring tongue terminal.(10 in-lb max)
P2 DC Output(Multiple) .156 friction lock header mates with Molex 09-50-3181 or equivalent crimp terminal housing with Molex 08-50-0189 or equivalent crimp terminal.
G Ground .187 quick disconnect terminal.
P3 Option/Sense(Single) .100 friction lock header mates with Molex 22-01-2087 or equivalent crimp terminal housing with Molex type 6459 or equivalent crimp terminal.
P3/P4 Option/Sense(Multiple)  .100 friction lock header mates with Molex 22-01-2047 or equivalent crimp terminal housing with Molex type 6459 or equivalent crimp terminal.
   RECOMMENDED AIR FLOW DIRECTION
  1.Optimum  2.Good  3.Fair
   
  About IPDProductsDownloadsInquiriesWhats NewContact Us



Integrated Power Design Inc.
Phone: 570-824-4666 Fax: 570-824-4843
300 Stewart Road, Wilkes Barre, PA 18706

We accept: