300 WATTS

     NO MINIMUM ORDER REQUIRED

CE-300 SERIES

     

 OUTPUT SPECIFICATIONS  
Features
  • RoHS Compliant 
  • Universal 85-264 VAC Input
  • Compact 4.9" X 8.5" X 1.95" Size
  • Class B Emissions Per EN 55022
  • 2 Year Warranty
  • EN 60950-1 ITE Certification
  • Harmonic Current per EN 61000-3-2
  • EMC to EN 61000-6-2
  • One to Five Regulated Outputs

Total Output Powerat 50C  300 W
Output Voltage Centering Output 1-5:  +/-0.5%
(All outputs at 50% load)
Source Regulation Outputs 1-5: 0.5%
Load Regulation
Output 1-5:1%              (10-100% Load Change)
Cross Regulation Output 2-5: 0.5%
(Output 1 load varied 50-100%)
Output Voltage Adjust Range Output 1-3: 95% to 105%
Output Noise Outputs 1-5: 1%
   
Turn On Overshoot None
Transient Response Outputs 1-5
Volt. Deviation 5%
Recovery Time 2 mS
Load Change 50% To 100%
Output Overvoltage Protection (Optional) Output 1: 120% to 150% Shuts down all outputs. Cycle input to restart.
Output Overpower Protection 340 W Min.
Outputs cycle on/off, auto recovery
Output Overcurrent Protection 110% Min,Outputs 2,3,4 & 5
Hold Up Time 20 mS Min, 300 W Output
120 V Inputt
Start Up Time 3 Second
   INPUT SPECIFICATIONS  
Source Voltage 85-264 Voltage AC
Frequency Range 47-63 Hz
Source Current  
True RMS 5.8A At 85V Inputut
Peak Inrush 20A
Peak Repetitive 8.2A at 85V Input
Harmonic Distortion 0.05
Efficiency .68 -.80 (Varies by model)
Power Factor 0.90(300W, 230V)
   ENVIRONMENTAL SPECIFICATIONS  
Ambient Operating Temperature Range 0oC to +70oC    Derating: See Power Rating Chart
Ambient Storage Temperature Range -40oC to +85oC
Temperature Coefficient Outputs 1-5: 0.02%/oC

   SAFETY SPECIFICATIONS  
   GENERAL SPECIFICATIONS  
General   Protection Class:

I

Overvoltage Category:

II

Pollution Degree:

2

Underwriters
Laboratories
File E137708
UL 60950-1 First Edition  

 

 

UL Recognition Mark for Canada
File E137708

CAN/CSA-C22.2 No. 60950-1-03

 

CB Report per IEC 60950-1(2001)      First Edition           All National Deviations

 
TUV EN 60950-1:2001  
  Low Voltage Directive  
Dielectric Strength  

Reinforced Insulation

4242 VDC, Primary to Secondary, 1 Sec.

Basic Insulation

2121 VDC, Primary to Ground, 1 Sec.

Operational Insulation

500 VDC, Secondary to Ground, 1 Sec.
Power Fail Signal Logic low with input power failure 2 mS minimum prior to output 1 dropping 1%
Remote On/Off (Optional) Contact closure shuts off all outputs
Remote Sense (outputs 1 & 2) 250mV compensation of output cable losses
Weight 3.30 Lbs. 
   MODEL LISTING
Model Output 1 Output 2 Output 3 Output 4 Output 5
CE-300-5001 +5V/40A +24V/4A +12V/6A -5V/1A -12V/2A
CE-300-5002 +5V/40A +12V/8A -12V/6A -5V/1A +24V/2A
CE-300-5003 +5V/40A +12V/8A +24V/3A -15V/1A +15V/2A
CE-300-5004 +5V/40A +24V/4A 24V/3A -12V/1A +12V/2A
CE-300-5005 +24V/8A +12V/8A +5V/6A -15V/1A +15V/2A
CE-300-5006 +24V/8A 24V/4A +5V/6A -15V/1A +15V/2A
CE-300-5012 +5V/40A +28V/3A +12V/6A -5V/2A -12V/2A
CE-300-5013 +5V/40A +3.3V/6A +24V/4A -5V/1A +12V/2A
CE-300-4001 +5V/40A +12V/8A -5V/5A   -12V/2A
CE-300-4002 +5V/40A +24V/4A +12V/6A   -12V/2A
CE-300-4003 +5V/40A +24V/4A +15V/4A   -15V/2A
CE-300-4004 +24V/8A +12V/8A +5V/6A   -12V/2A
CE-300-4005 +5V/40A -5.2V/12A 12V/6A   -12V/2A

CE-300-4006

CE-300-4007

+24V/8A

+24V/8A

+12V/8A

+15V/6A

 

+5V/6A

-12V/1.5A

 

5V/2A

-15V/2A

CE-300-4009 +24V/8A +12V/8A +5V/10A   -12V/2A
CE-300-4011 +5V/40A +3.3V/12A   +12V/2A -12V/2A
CE-300-3001 +5V/40A +12V/8A -12V/6A    
CE-300-3002 +5V/40A +12V/8V +24V/3A    
CE-300-3003 +5V/40A +15V/6A -15V/4A    
CE-300-3004 +12V/16A -12V/8A +5V/6A    
CE-300-3006 +5V/40A +3.3V/12A   +12V/2A  
CE-300-2001 +5V/40A +24V/4A      
CE-300-2002 +12V/16A -12V/8A      
CE-300-2003 +15V/13A -15V/6A      
CE-300-2004 +24V/8A -24V/4A      
CE-300-1001 5V/60A        
CE-300-1002 12V/25A        
CE-300-1003 15V/20A        
CE-300-1004 24V/12A        
ELECTROMAGNETIC COMPATIBILITY
Electrostatic Discharge EN 61000-4-2 +/-8kV Contact Discharge
+/-8kV Air Discharge
Radiated Electromagnetic Field EN 61000-4-3 80MHz-2.5GHz, 10V/m, 80% AM
EFT/Bursts EN 61000-4-4 +/-2kV
Surges EN 61000-4-5 +/-1 kV Differential Mode
+/-2 kV Common Mode
Conducted Immunity EN 61000-4-6 .15-80MHz., 10V, 80% AM
Voltage Dips and Interruptions EN 61000-4-11 30% Reduction,500mS
95% Reduction,10mS
60% Reduction, 1s (Criteria B)
95% Reduction,5000ms
Radiated Emissions EN 55011/22 Class B
Conducted Emissions EN 55011/22 Class B
Harmonic Current Emissions EN 61000-3-2  
   Notes
  Consult factory for alternate output configuration.
Consult factory for positive, negative or floating outputs.
Refer to Application Information for complete output power ratings.
All specifications are maximum at 25oC unless otherwise stated and are subjected to change without notice.
Specify optional power fail, overvoltage protection or remote on/off when ordering.
CE-300-4006: TUV only
   CE-300 SERIES MECHANICAL SPECIFICATIONS  

 

 

 

 

 

 

 Maximum Output Power vs. Ambient Temperature

   CONNECTOR SPECIFICATIONS
TB1 AC Input Terminal Block with 6-32 screws on 0.325 centers mates with #6.0.25 inch wide spade terminals. (10 in-lb max)
TB2 DC Output Terminal Block with 6-32 screws on 0.325 centers mates with #6.0.25 inch wide spade terminals. (10 in-lb max)
+/- DC Output 10-32 threaded studs mate with #10 ring tongue terminals.
P1 Option/Sense .100 breakaway header mates with Molex 22-01-2127 or equivalent crimp terminal housing with Molex 6459 or equivalent crimp terminal.

   APPLICATIONS INFORMATION
  1. Semiconductor case temperature must not exceed 110 oC.
  2. Each output can deliver its rated current but total output power must not exceed
    300 watts.   
  3. Remote sense terminals may be used to compensate for cable losses up to 250mV. The use of a twisted pair is recommended as well as a decoupling capacitor (0.1-10uF) and a capacitor of 100uF/amp connected across the load side.
  4. Sufficient area must be provided around convection cooled power supplies to allow natural movement of air develop.
  5. This product is intended for use as a professionally installed component within information technology and medical equipment.
  6. A minimum load of 10% is required on output one to insure proper regulation of remaining outputs.  
  7. Peak to peak output ripple and noise is measured directly at the output
    terminals of the power supply, without the use of the probe ground lead or retractable tip, 20 MHz bandwidth. 
  8. This product was type tested and safety certificated using the the dielectric strength test voltages listed in Table V of UL 60950. In consideration of clause 5.2.2, care must be taken to insure the voltage applied to a reinforced insulation does not over stress basic insulation. Secondary to ground capacitors may need to be removed prior to performing a dielectric strength type test on the end product. It is highly recommended that the DC test voltages be used when performing a production-line dielectric strength test of the assembled end product. Please consult factory for further information.
  9. This power supply has been safety approved and final tested using a DC
    dielectric strength test. Please consult factory before performing AC dielectric strength test.
  10. Maximum screw penetration into mounting holes is .188 inches
   