25 WATTS

    NO MINIMUM ORDER REQUIRED

SRP-25 SERIES

     

 OUTPUT SPECIFICATIONS  
Features
  • RoHS Compliant
  • Universal 85-264 VAC Input
  • Advanced SMT Design
  • Compact 2.25" X 4.0" X .96" Size
  • Class B Emissions Per EN 55011/22
  • EMC to EN 61000-6-2 & EN 60601-1-2
  • 2 Year Warranty
  • Fits 1U Application
  • EN 60950 ITE Certification
  • EN 60601-1 Medical Certification
  • Optional Chasis & Cover
  • One to Three Outputs

Total Output Power at 50C 25 W (20W, 1001)
Output Voltage Centering Output 1: +/-0.25%
Output 2: +/-5.0%
Output 3: +/-2.0%
(All outputs at 50% rated load)
Source Regulation Outputs 1-3: 0.5%
Load Regulation

Output 1:0.5% (0-100% Load Change)
Output 2: 5.0% (10-100% Load Change)
Output 2:(2003) 6.0% (30-100% Load Change)
Output 3: 1.0% (0-100% Load Change)

Cross Regulation Output 2: 5.0%
Output 3: 2.0%
(Output 1 load varied 50-100%)
Output Voltage Adjust Range  Output 1: 95% to 105%
Output Noise Outputs 1-3: 1%
Turn On Overshoot None
Transient Response Outputs 1-3
Volt. Deviation 5.0%
Recovery Time 1 mS
Load Change 50% To 100%
Output Overvoltage Protection Output 1: 110% to 150%
Output Overpower Protection Output 1 & 2  110% Min.
Outputs cycle on/off, auto recovery
Output Overcurrent Protection Output 3      110% Min.
Hold Up Time 10 mS Min, 25W Output
120V Input
Start Up Time 1 Second
   INPUT SPECIFICATIONS  
Source Voltage 85-264 Voltage AC
Frequency Range 47-63 Hz
Source Current  
True RMS .8A At 85V Input
Peak Inrush 30A
Efficiency .66 -.72 (Varies by model)
   ENVIRONMENTAL SPECIFICATIONS  
Ambient Operating Temperature Range

0oC to +70oC

Derating: See Power Rating Chart

Ambient Storage Temperature Range -40oC to +85oC
Temperature Coefficient Outputs 1-3: 0.02%/oC

   SAFETY SPECIFICATIONS  
   GENERAL SPECIFICATIONS  
General   Protection Class:

I

Overvoltage Category:

II

Pollution Degree:

2

 

 

Underwriters
Laboratories
File E137708

 

UL 60950-1 First Edition             UL 60601-1           First Edition

CB Report per IEC 60950-1(2001)       First Edition             All National Deviations  CB Report per IEC 60601-1(1988)  Second Edition A1, A2

 
UL Recognition Mark for Canada
File E137708

CAN/CSA-C22.2 No. 60950-1-03   CAN/CSA-C22.2 No. 601-1-M90             with updates 1 and 2

 
TUV EN 60950-1:2001
EN 60601-1/A2: 1995
 
  Low Voltage Directive  

Dielectric Strength

 

 

 Reinforced Insulation        

5656 VDC, Primary to Secondary, 1 Sec.

 Basic Insulation

2121 VDC, Primary to Ground, 1 Sec.

Operational Insulation

707 VDC, Secondary to Ground, 1 Sec.
Leakage Current <300µA Earth Leakage Current
Mean-Time Between Failures 100,000 Hours min., MIL-HDBK-217F, 25oC, GB
Weight 0.62 Lbs.  Chassis and Cover
0.30 Lbs.  Open Frame
 

ELECTROMAGNETIC COMPATIBILITY SPECIFICATIONS

Electrostatic Discharge EN 61000-4-2  +/-8kV Contact Discharge
+/-8kVAir Discharge
Radiated Electro-magnetic Field EN 61000-4-3  80MHz-2.5GHz, 10V/m, 80% AM
EFT/Bursts EN 61000-4-4 +/-2kV
Surges EN 61000-4-5 +/-1 kV Differential Mode
+/-2 kV Common Mode
Conducted Immunity EN 61000-4-6 .15to80MHz., 10V, 80% AM
Voltage Dips and Interuptions EN 61000-4-11 30%Reduction,500ms
95% Reduction,10ms
60% Reduction,1s(Criteria B)
95% Reduction,500ms
Radiated Emissions EN 55011/22 Class B
Conducted Emissions EN 55011/22 Class B
   Notes  
Consult factory for alternate output configuration.
Consult factory for positive, negative or floating output 2 or 3.
Refer to Application Information for complete output power ratings.

All specifications are maximum at 25C unless otherwise stated and are subjected to change without notice.
Specify optional chassis and cover when ordering.
   MODEL LISTING
Model Output 1 Output 2 Output 3
SRP-25-3001 +5V/3A +12V/1.5A -12V/.5A

SRP-25-3002

SRP-25-3003          

+5V/3A

3.3V/2.5A

+15V/1.5A

6V/2A

-15V/.5A

5V/1A

SRP-25-2001 +5V/3A +24V/1A  
SRP-25-2002 +5V/3A +12V/1.5A  
SRP-25-2003 +5V/3A -5V/2A  
SRP-25-2004 +12V/1.5A -12V/1.5A  
SRP-25-2005 +15V/1.5A -15V/1.5A  
SRP-25-1001 3.3V/6A    
SRP-25-1002 5V/5A    
SRP-25-1003 12V/2.08A    
SRP-25-1004 15V/1.67A    
SRP-25-1005 24V/1.04A    
SRP-25-1006 48V/0.52A    

 

   SRP-25 SERIES MECHANICAL SPECIFICATIONS  

 

 

 

   APPLICATIONS INFORMATION
  1. Each output can deliver its rated current but total output power must not exceed
    25 watts. 
  2. Semiconductor case temperature must not exceed 110 oC
  3. Sufficient area must be provided around convection cooled power supplies to allow natural movement of air develop.
  4. This product is intended for use as a professionally installed component within information technology and medical equipment.
  5. A minimum load of 10% is required on output one to insure proper regulation of
    remaining outputs.
  6. Peak to peak output ripple and noise is measured directly at the output
    terminals of the power supply, without the use of the probe ground lead or retractable tip, 20 MHz bandwidth.
  7. This product includes only one fuse in the input circuit. In consideration of clause 57.6 of UL 2601-1, a second fuse may be required in the end product.
  8. This product was type tested and safety certificated using the the dielectric strength test voltages listed in Table V of UL 60601-1. In consideration of clause 20.4g, care must be taken to insure the voltage applied to a reinforced insulation does not over stress basic insulation. Secondary to ground capacitors may need to be removed prior to performing a dielectric strength type test on the end product. It is highly recommended that the DC test voltages listed in DVB.1. Annex DVB are not exceeded during a production-line dielectric strength test of the assembled end product. Please consult factory for further information.
  9. This power supply has been safety approved and final tested using a DC
    dielectric strength test. Please consult factory before performing AC dielectric strength test.
 
  1. Maximum screw penetration into bottom chassis mounting holes is .100 inches.
  2.  Maximum screw penetration into side chassis mounting holes is .250 inches.
  3. To meet emissions specifications, all four mounting hole ground pads must
    be electrically connected. Use metal standoffs attached to a common metal chassis or base plate.
 

 Maximum Output Power vs. Ambient Temperature

   CONNECTOR SPECIFICATIONS
P1 AC Input .156 friction lock header mates with Molex 09-50-3031 or equivalent crimp terminal housing with Molex 08-50-0189 or equivalent crimp terminal.
P2 DC Output .156 friction lock header mates with Molex 09-50-3061 or equivalent crimp terminal housing with Molex 08-50-0189 or equivalent crimp terminal.
G Ground .187 quick disconnect terminal.
   RECOMMENDED AIR FLOW DIRECTION
  1. Optimum
  2. Good
  3. Fair
   