175 WATTS |
NO MINIMUM ORDER REQUIRED |
|
NXT-175 SERIES |
|
Features
- RoHS Compliant
- 2 Year Warranty
- High Efficiency, 85% typical
- High Power Density,9.3 W/cu in.
- Compact 3.0" X 5.0" X 1.25" Size
- EN 60950-1 ITE Certification
- EN 60601-1 Medical Certification
- EMC to EN 61000-6-2 & EN 60601-1-2
- Advanced SMT Design
- Optional Chasis & Cover
- Optional Single Wire Load Sharing
- Optional Remote Inhibit/Enable

|
| Total Output Power at 50C |
115w Convection Cooled, Open Frame 175W 300 LFM Forced Air, Open Frame |
| Power Derating |
1.0 Wout / 1Vin below 100 Vin |
| Voltage Centering |
+/-0.5% (50% Load) |
| Voltage Adjust Range |
95-105% |
| Load Regulation |
0.5% (0-100% load change) |
| Source Regulation |
0.5% |
| Noise |
1.0% or 100mV Whichever is greater |
| Transient Response |
Output recovers to within 1% of initial set point due to a 50% step load change, 500uS maximum, 4% maximum deviation. |
|
|
| |
|
|
|
|
|
| Turn on Overshoot |
None |
| Overvoltage Protection |
Latching, between 110% and 150% of rated output voltage. |
|
| Overpower Protection |
110-130% rated Pout, cycle on/off, auto recovery |
| Hold Up Time |
16 mS min., Full Power, 85-264V Input |
| Start Up Time |
3 Seconds, 120V Input | |
|
|
|
| General |
|
Protection Class: |
I |
| Overvoltage Category: |
II |
| Pollution Degree: |
2 |
|


|
Underwriters Laboratories File E137708/E140259
|
UL 60950-1 First Edition UL 60601-1 First Edition
CB Report per IEC 60950-1(2001) First Edition All National Deviations CB Certificates per IEC 60601-1(1988) Second Edition A1, A2 |
|
 |
UL Recognition Mark for Canada File E137708/E140259 |
CAN/CSA-C22.2 No. 60950-1-03 CAN/CSA-C22.2 No. 601-1-M90 with updates 1 and 2 |
|
 |
TUV |
EN 60950-1:2001 EN 60601-1/A2: 1995 |
|
 |
|
Low Voltage Directive |
|
|
Reinforced Insulation |
5656 VDC,Primary to Secondary,1 Sec. |
| Basic Insulation |
2545 VDC,Primary to Ground,1 Sec. |
| Operational Insulation |
707 VDC,Secondary to Ground,1 Sec. |
| Leakage Current |
<300uA Earth Leakage Current |
| Power Fail Signal |
Logic low with input power failure 10 ms minimum prior to output 1 droppping 1%. |
|
Remote Inhibit (optional) |
Isolated. Contact closure inhibits output. |
| Load Share (optional) |
Single wire current sharing with return via negative sense return. Minimum current share load is 10% of each module's output current rating. Maximum output voltage deviation between modules is 5% for 2.5 through 5V models and 400mV for remaining models. |
| Standby Power (optional) |
Isolated 5Vdc +/- 10%,10mA available only with Remote Inhibit option. |
| Remote Sense |
400mV compensation of output cable losses |
| Mean-Time Between Failures |
100,000 Hours min.,MIL-HDBK-217F,25 C,GB |
| Weight |
0.85 Lbs Open Frame 1.37 Lbs Chassis and Cover | S
|
ELECTROMAGNETIC COMPATIBILITY SPECIFICATIONS | |
|
Electrostatic Discharge |
EN 61000-4-2 |
+/-6kVContact Discharge +/-8kV Air Discharge |
|
Radiated Electro-magnetic Field |
EN 61000-4-3 |
80-2500MHz, 10V/m, 80%AM |
|
EFT/Bursts |
EN 61000-4-4 |
+/-2kV |
|
Surges |
EN 61000-4-5 |
+/-2kV Line to Earth +/-1kV Line to Line |
|
Conducted Immunity |
EN 61000-4-6 |
.15-80MHz., 10V, 80% AM |
|
Voltage Dips |
EN 61000-4-11 |
95% Dip,10ms 30% Dip,500ms 60% Reduction, 1s (Criteria B) |
|
|
|
|
|
|
|
Voltage Interruptions |
EN 61000-4-11 |
95% Reduction,5s |
|
Radiated Emissions |
EN 55011/22, FCC Part 15 |
Class B |
| Conducted Emissions |
EN 55011/22, FCC Part 15 |
Class B |
| Harmonic Current Emissions |
EN 61000-3-2 |
Compliance |
| Magnetic Field Immunity |
EN 61000-4-8 |
30A/m, 50/60Hz. |
| Voltage Fluctuations and Flicker |
EN 61000-3-3 |
Compliance |
| Power Factor |
EN 61000-3-2 |
Compliance | |
|
Source Voltage |
85-264 Volts AC, 120-370 Volts DC |
|
|
|
|
|
|
|
|
|
| Frequency Range |
47-63 Hz |
| Input Protection |
Internal 5A Time Delay fuse |
| Peak Inrush Current |
50A (cold) |
| Efficiency |
85% Typical, Full Power varies by model |
| Power Factor |
0.95 (Full Power,230V), 0.98(Full Power, 120V) |
|
ENVIROMENTAL SPECIFICATIONS |
|
Ambient Operating |
00C to + 700C |
|
|
|
|
Temperature Range |
Derating:See Power Rating Chart |
|
|
|
|
Ambient Storage Temp. Range |
-40oC to +85oC |
|
Operating Relative Humidity Range |
20-90% non-condensing |
|
Altitude |
10,000ft. ASL Operating 40,000ft. ASL Non-operating |
|
Temperature Coefficient |
0.02%/oC |
|
Vibration |
2.5g, 10Hz.-2KHz per MIL-STD-810F Method 514.5 |
| Shock |
20g, peak per MIL-STD-810F Method 516.5 |
Please specify the following optional features when ordering: C - Chassis CO -Cover RI - Remote Inhibit LS - Single Wire Load Sharing LSEVB - Load Share Evaluation Board
All specifications are maximum at 25o C unless otherwise stated and are subject to change without notice.
 |
AC Input |
.156 friction lock header mates with Molex 09-50-3031 or equivalent crimp terminal housing with Molex 2478 or equivalent crimp terminal. |
|
|
|
|
|
|

|
DC Output |
6-32 screw down terminal mates with #6 ring tongue terminal.(10 in-lb Max) |
|
 |
Power Fail, Load Share,Sense |
.100 friction lock header mates with Molex 22-55-2081 or equivalant crimp terminal housingwith Molex 71851 or crimp equivalent terminal. |
|
 |
Inhibit,Standby Power |
.100 friction lock header mates with Molex 22-55-2041 or equivalent crimp terminal housing with Molex 71851 or equivalent crimp terminal. |
|
 |
Ground |
.187 quick disconnect terminal. |
| |
| Model |
OPEN 300 LFM |
FRAME CONVECTION |
CHASSIS/ 300 LFM |
COVER CONVECTION |
|
|
COOLED |
|
COOLED |
| NXT-175-1001 |
2.5V/35.0A |
2.5V/23.0A |
2.5V/31.5A |
2.5V/20.7A |
| NXT-175-1002 |
3.3V/35.0A |
3.3V/23.0A |
3.3V/31.5A |
3.3V/20.7A |
| NXT-175-1003 |
5V/35.0A |
5V/23.0A |
5V/31.5A |
5V/20.7A |
| NXT-175-1004 |
12V/14.6A |
12V/9.6A |
12V/13.1A |
12V/8.6A |
| NXT-175-1005 |
15V/11.7A |
15V/7.7A |
15V/10.5A |
15V/6.9A |
| NXT-175-1006 |
24V/7.3A |
24V/4.8A |
24V/6.6A |
24V/4.3A |
| NXT-175-1007 |
28V/6.3A |
28V/4.1A |
28V/5.6A |
28V/3.7A |
| NXT-175-1008 |
48V/3.6A |
48V/2.4A |
48V/3.2A |
48V/2.2A |
|
NXT-175 SERIES MECHANICAL SPECIFICATIONS |





|
|
- Sufficient area must be provided around power supply to allow natural movement of air to develop in convection cooled applications.
- 300 linear feet per minute of airflow must be maintained one inch above the top of the heatsinks in any direction in open frame forced air applications.
- 300 linear feet per minute of airflow must be maintained one inch above and toward any of the three perforated sides of the cover in forced air chassis/cover applications.
- Generally, adequate cooling is provided when semiconductor case temperatures do not exceed 70 C rise and transformer temperature does not exceed 60 C rise at any specified ambient temperature.
- This product is intended for use as a professionally installed component within information technology, industrial and medical equipment and is not intended for stand alone operation. Common RF shielding precautions may need to be taken to assure emissions compliance. Refer to operating instructions for additional information.
- This product includes only one fuse in the input circuit. In consideration of clause 57.6 of UL 60601-1, a second fuse may be required in the end product.
- Low forward voltage drop oring diodes must be used in all load sharing applications in 2.5 through 15 Volt models. Oring diodes must be used on 24 through 48 Volt models used in fault tolerant applications but are optional in power boosting applications. Oring diode power dissipation must be subtracted from the maximum output power rating of each model.
- Current carrying conductors in load sharing applications must be short and symmetrical. Remote sense conductors should be a twisted pair. The use of an appropriately rated low impedance capacitor across the load will increase noise immunity.
- Refer to Load Share Evaluation Board data sheet (page 58) for additional load share applications information.
|
- Remote sense terminals may be used to compensate for cable losses up to 400 mV depending on model. The use of a twisted pair, decoupling capacitors and an appropriately rated low impedance capacitor connected across the load will increase noise immunity.
- A load equal to 5% rated output power must be maintained when using standby power option. An external electrolytic capacitor across standby power output may be used to improve transient response.
- Peak to peak output ripple and noise is measured directly at the output terminals of the power supply, without the use of the probe ground lead or retractable tip, 20 MHz bandwidth.
- This product was type tested and safety certified using the dielectric strenght test voltages listed in Table V of UL 60601-1. In consideration of Clause 20.4g, care must be taken to insure that the voltage applied to a reinforced insulation does not overstress basic insulation. Secondary to ground capacitors may need to be removed prior to performing a dielectric strenght type test on the end product. It is highly recommended that the DC test Voltages listed in DVB.1, Annex DVB are not exceeded during a production-line dielectric strength test of the assembled end product. Please consult factory for further information.
- This power supply has been safety approved and final tested using a DC dielectric strength test. Please consult factory before performing an AC dielectric strength test.
- Maximum screw penetration into bottom chassis mounting holes is .100 inches.
- Maximum screw penetration into side chassis mounting holes is .188 inches.
- To comply with emissions specifications, all four mounting hole pads must be electrically connected to a common metal chassis. Chassis/cover option recommended.
|
Maximum Output Power vs. Ambient Temperature | |
|

|
Derating requirements- The chart above applies to models 1003 through 1008 only. 175 Watts with 300 LFM forced air, open frame. 115 Watts convection cooled, open frame. Derate 10% with chassis and cover. Derate 1.0 Wout / 1 Vin below 100 Vin between 100 Vin and 85 Vin. Use larger of the two deratings when using chassis/cover below 100 Vin. Derate output power linearly to 50% between 50o C and 70o C.
|
TYPICAL LOAD SHARE/REMOTE SENSE APPLICATION |
|

|