300 Watts

CE-300 Series

FEATURES

  • RoHS Compliant
  • Universal 85-264 VAC Input
  • Compact 4.9” x 8.5” x 1.95” Size
  • 2 Year Warranty
  • One to Four Tightly Regulated Outputs
  • EN 60950-1 ITE Certification
  • Class B Emissions per EN 55022
  • Harmonic Current per EN 61000-3-2
  • EMC to EN 61000-6-2

Product Downloads

Full Data Sheet w/ 3rd Edition Approval

CB Certificate with Attachments

Operating Instructions / Declaration of Conformity

RoHS Declaration

Check Available Inventory

MODEL LISTING

model

output 1

output 2

output 3

output 4

output 5

CE-300-5001
CE-300-5002
CE-300-5003
CE-300-5004
CE-300-5005
CE-300-5006
CE-300-5012
CE-300-5013
CE-300-4001
CE-300-4002
CE-300-4003
CE-300-4004
CE-300-4005
CE-300-4006
CE-300-4007
CE-300-4009
CE-300-4011
CE-300-3001
CE-300-3002
CE-300-3003
CE-300-3004
CE-300-3006
CE-300-2001
CE-300-2002
CE-300-2003
CE-300-2004
CE-300-1001
CE-300-1002
CE-300-1003
CE-300-1004
+5V/40A
+5V/40A
+5V/40A
+5V/40A
+24V/8A
+24V/8A
+5V/40A
+5V/40A
+5V/40A
+5V/40A
+5V/40A
+24V/8A
+5V/40A
+24V/8A
+24V/8A
+24V/8A
+5V/40A
+5V/40A
+5V/40A
+5V/40A
+12V/16A
+5V/40A
+5V/40A
+12V/16A
+15V/13A
+24V/8A
5V/60A
12V/25A
15V/20A
24V/12A
+24V/4A
+12V/8A
+12V/8A
+24V/4A
+12V/8A
24V/4A
+28V/3A
+3.3V/6A
+12V/8A
+24V/4A
+24V/4A
+12V/8A
-5.2V/12A
+12V/8A
+15V/6A
+12V/8A
+3.3/12A
+12V/8A
+12V/8A
+15V/6A
+12V/8A
+3.3/12A
+24V/4A
-12V/8A
-15V/6A
-24V/4A
+12V/6A
-12V/6A
+24V/3A
24V/3A
+5V/6A
+5V/6A
+12V/6A
+24V/4A
-5V/5A
+12V/6A
+15V/4A
+5V/6A
+12V/6A
-
+5V/6A
+5V/10A
-
-12V/6A
+24V/3A
-15V/4A
+5V/6A
-5V/1A
-5V/1A
-15V/1A
-12V/1A
-15V/1A
-15V/1A
-5V/2A
-5V/1A
-
-
-
-
-
-12V/1.5A
-
-
+12V/2A
-
-
-
-
+12V/2A
-12V/2A
+24V/2A
+15V/2A
+12V/2A
+15V/2A
+15V/2A
-12V/2A
12V/2A
-12V/2A
-12V/2A
-15V/2A
-12V/2A
-12V/2A
5V/2A
-15V/2A
-12V/2A
-12V/2A

INPUT SPECIFICATIONS

Source Voltage
Frequency Range
Source Current
True RMS
Peak Inrush
Peak Repetitive
Harmonic Distortion
Efficiency
Power Factor
85 – 264 Volts AC
47 – 63 Hz
-
5.8A at 85V Input
20A
8.2A at 85V Input
0.05
.68-.80(varies by model)
0.90 (300 W, 230V)

OUTPUT SPECIFICATIONS

Total Output Power
Output Voltage Centering
Output Voltage Adjust Range
Load Regulation
Source Regulation
Cross Regulation
Output Noise
Turn on Overshoot
Transient Response
Voltage Deviation
Recovery Time
Load Change
Output Overvoltage Protection
(Optional)
Output Overpower Protection
Output Overcurrent Protection
Hold Up Time
Start Up Time
300W
Output 1-5: ± 0.5% (All outputs at 50% load)
Outputs 1 –3: 95-105%
Outputs 1 – 5: 1.0% (10-100% load change)
Outputs 1 – 5: 0.5%
Outputs 2 – 5: 0.5% (Output 1 load varied 50-100%)
Outputs 1 – 5: 1.0%
None
Outputs 1 – 5
5.0%
2mS
50% to 100%
Output 1: 120% to 150% Shuts down all outputs. Cycle input to restart.
340 W Min.,
Outputs cycle on/off, auto recovery
Outputs 2,3,4 & 5, 110% Min
20 mS min., 300W Output, 120V Input
3 Seconds

SAFETY & ELECTROMAGNETIC COMPATIBILITY SPECIFICATIONS

Safety Approvals
Electrostatic Discharge
-
Radiated Electromagnetic Field
EFT/Bursts
Surges
-
Conducted Immunity
Radiated Emissions
Conducted Emissions
Harmonic Current Emissions
Voltage Dips and Interruptions
EN 60950-1/A12:2011
EN 61000-4-2 ±8kV Contact Discharge
±8kV Air Discharge
EN 61000-4-3 80MHz-2.5GHz, 10/m, 80% AM
EN 61000-4-4 ±2 kV
EN 61000-4-5 ±2 kV Common Mode
+\-1 kV Differential Mode
EN 61000-4-6 .15 to 80MHz, 10V, 80% AM
EN 55011/22 Class B
EN 55011/22 Class B
EN 61000-3-2
EN 61000-4-11 30% Reduction, 500ms
95% Reduction, 10ms

60% Reduction, 1s (Criteria B)
95% Reductions, 5000ms

ENVIRONMENTAL SPECIFICATIONS

Ambient Operating
Temperature Range
Ambient Storage Temp. Range
Temperature Coefficient
0° C to + 50° C
Derating: See Power Rating Chart on Data Sheet
– 40° C to + 85° C
Outputs 1-5: 0.02%/ °C

GENERAL SPECIFICATIONS

Dielectric Strength(8)
Reinforced Insulation
Basic Insulation
Operational Insulation
Power Fail Signal
-
Remote On/Off (optional)
Remote Sense(outputs 1&2)
Weight
-
4242 VDC, Primary to Secondary, 1 Sec.
2121 VDC, Primary to Ground, 1 Sec.
500 VDC, Secondary to Ground, 1 Sec.
Logic low with input power failure 2 mS
minimum prior to Output 1 dropping 1%
Contact closure shuts off all outputs
250mV compensation of output cable losses
3.30 Lbs.

All specifications are maximum at 25° C, unless otherwise stated, may vary by model and are subject to change without notice.       