IEC 60601-1 3rd Edition – Medical Power Supplies

 

 Our design and safety engineers at Integrated Power Designs (IPD) are keenly aware of the arduous process that medical equipment designers face when creating new and innovative products.  We constantly track upcoming changes in the 60601-1 medical standard and make sure that our medical power supplies meet or exceed the latest requirements.  Having our power supplies always meet the most recent standard before it goes into effect gives you the product you need, when you need it.   The most recent CB Certificates can be downloaded from our individual product pages.

 All of IPD’s products are designed, tested and manufactured at one site.  This allows us to keep tight constraints on all quality controls for our power supplies.  There is no “dis-connect” from using different facilities around the world. 

 IPD Medical Power Supply Quick Reference

 IPD Medical Power Supplies 

      Series      Outputs            Rated Input         Output Power

      SRP-25       
SRP-40A
SRP/SRW-100
GRN-45
GRN-60
GRN-80S
GRN-80M
GRN-110S
GRN-110M
DC2-70
DC2-110
DC2-150
DC2-185
DC4-70
DC4-110
DC4-150
DC4-185
REL-70
REL-110
REL-150
REL-185
CE-150
CE-225
NXT-100
NXT-175
NXT-225
NXT-325
NXT-400
        3        
4
4
4
1
1
4
1
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
1
1
1
1
1
         85-264VAC, 50-60Hz         
85-264VAC, 50-60Hz
85-264VAC, 50-60Hz
85-264VAC, 50-60Hz
85-264VAC, 50-60Hz
85-264VAC, 50-60Hz
85-264VAC, 50-60Hz
85-264VAC, 50-60Hz
85-264VAC, 50-60Hz
18-36VDC
18-36VDC
18-36VDC
18-36VDC
36-72VDC
36-72VDC
36-72VDC
36-72VDC
85-264VAC, 50-60Hz
85-264VAC, 50-60Hz
85-264VAC, 50-60Hz
85-264VAC, 50-60Hz
85-264VAC, 50-60Hz
85-264VAC, 50-60Hz
85-264VAC, 50-60Hz
85-264VAC, 50-60Hz
85-264VAC, 50-60Hz
85-264VAC, 50-60Hz
85-264VAC, 50-60Hz
               25               
40
100
45
60
80
80
110
110
70
110
150
185
70
110
150
185
70
110
150
185
150
225
100
175
225
325
400

Safety Approvals
EU            EN60601-1:2005
USA         ANSI/AAMI ES 60601-1:2005
Canada    CSA-C2.2 No. 60601-1:2008

Transition from 60601-1 2nd Edition to 60601-1 3rd Edition
The major differences between 60601-1 2nd Edition and 60601-1 3rd edition are the inclusion of risk management analysis and MOOP (means of operator protection) and MOPP (means of patient protection) in regards to creepage/clearance and dielectric requirements.The risk management analysis is not required of component power supplies, however we know that when designing equipment, more information is always better and have completed the risk management for our power supplies.  This information is available upon request to our customers. All IPD medical power supplies have been approved to the 60601-1 3rd edition standard and are available with:2MOPP primary to secondary isolation (AC-DC products)2MOOP primary to secondary isolation (DC-DC products)
 
Emission and Immunity Specifications (AC-DC Models only)
 
EN 55011/22, FCC Part 15                     Conducted Emissions
EN 55022/22, FCC Part 15                     Radiated Emissions
EN 61000-3-2                            Harmonic Current Emissions
EN 61000-3-3                            Voltage Fluctuations and Flicker
EN 61000-4-2                            Electrostatic Discharge
EN 61000-4-3                            Radiated Electromagnetic Field
EN 61000-4-4                            EFT/Bursts
EN 61000-4-5                            Surges
EN 61000-4-6                            Conducted Emissions
EN 61000-4-8                            Magnetic Field Immunity
EN 61000-4-11                           Voltage Dips / Interruptions

 IEC 60601-1 3rd Edition Medical Power Supplies Healthcare MOP MOOP AC-DC DC-DC