40 Watts

SRP-40A Series

FEATURES

  • RoHS Compliant
  • Universal 85-264 VAC Input
  • Advanced SMT Design
  • Compact 2.5” x 4.25” x 1.2” Size
  • 2 Year Warranty
  • Fits 1U Applications
  • One to Four Outputs
  • EN 60950-1 ITE Certification
  • EN 60601-1 Medical Certification
  • Class B Emissions per EN 55011/22
  • EMC to EN 61000-6-2 & EN 60601-1-2
  • Optional Chassis & Cover

Product Downloads

Full Data Sheet w/ 3rd Edition Approval

CB Certificate with Attachments

Operating Instructions / Declaration of Conformity

RoHS Declaration

Check Available Inventory

MODEL LISTING

model

output 1

output 2

output 3

output 4

SRP-40A-4001
SRP-40A-4002
SRP-40A-4003
SRP-40A-4004
SRP-40A-4005
SRP-40A-4006
SRP-40A-3001
SRP-40A-3002
SRP-40A-3003
SRP-40A-3004
SRP-40A-3005
SRP-40A-2001
SRP-40A-2002
SRP-40A-2003
SRP-40A-2004
SRP-40A-2005
SRP-40A-2006
SRP-40A-2007
SRP-40A-2008
SRP-40A-1001
SRP-40A-1002
SRP-40A-1003
SRP-40A-1004
SRP-40A-1005
SRP-40A-1006
SRP-40A-1007
+3.3V/5A
+5V/5A
+5V/5A
+5V/5A
+5V/5A
+3.3V/3.1A
+5V/5A
+5V/5A
+24V/1.5A
+14.5V/1.5A
+5.1V/5A
+5V/5A
+5V/5A
+5V/5A
+12V/3A
+15V/2.5A
+30V/1.2A
+3.3V/5A
+6V/5A
3.3V/10A
5V/8A
12V/3.33A
15V/2.67A
24V/1.67A
48V/0.83A
9V/4.45A
+5V/3A
+3.3V/3A
-5V/3A
-5V/3A
+24V/1.5A
+5V/1.25A
+12V/2A
+15V/2A
-
-14.5V/1.5A
+15V/2A
+24V/1.5A
-5V/4A
-12V/3A
-15V/2A
-
-
-
+9V/1.1A
+12V/0.7A
+12V/0.7A
+12V/0.7A
+15V/0.7A
+12V/0.7A
+15V/0.7A
-12V/0.7A
-15V/0.7A
-51.6/.25A
+5V/1A
+9V/0.7A
-
-
-
-
-
-15V/0.7A
+5V/0.7A
-12V/0.7A
-12V/0.7A
-12V/0.7A
-15V/0.7A
-12V/0.7A
-51.6V/0.25A
-
-
-15V/0.7A

INPUT SPECIFICATIONS

Source Voltage
Frequency Range
Source Current
True RMS
Peak Inrush
Efficiency
85 – 264 Volts AC
47 – 63 Hz
-
1A at 85V Input
30 A
.66 – .80 (Varies by model)

OUTPUT SPECIFICATIONS

Total Output Power
Output Voltage Centering
-
-
-
Output Voltage Adjust Range
Load Regulation V1
V2
-
V3
V4
Source Regulation
Cross Regulation
-
-
Output Noise
Turn on Overshoot
Transient Response
Voltage Deviation
Recovery Time
Load Change
Output Overvoltage Protection
Output Overcurrent Protection
Output Overpower Protection
-
Hold Up Time
Start Up Time
40W (33W, 1001 )
Output 1: ± 0.25% (All outputs at 50% load)
Output 2: ±5.0%
Output 3: ±3.0%
Output 4: ±3.0%
Output 1: 95 – 105%
Output 1: 0.5% (0-100% load change)
Output 2: 5.0% (30-100% load change)
Output 2: (2003,4002) 7.0% (30-100% load change)
Output 3: 0.5% (10-100% load change)
Output 4: 0.5% (10-100% load change)
Outputs 1 – 4: 0.5%
Output 2: 5.0% (Output 1 load varied 50-100%)
Output 3: 0.5%
Output 4: 0.5%
Outputs 1-4 1%
None
Outputs 1 – 4
5.0%
2 mS
50% to 100%
Output 1: 110% to 150%
Output 3&4: 110% Min.
Outputs 1 & 2: 110% Min.
Outputs cycle on/off, auto recovery
10 mS min., 25W Output, 120V Input
1 Second

SAFETY & ELECTROMAGNETIC COMPATIBILITY SPECIFICATIONS

Safety Approvals
-
-
Electrostatic Discharge
Radiated Electromagnetic Field
EFT/Bursts
Surges
Conducted Immunity
Voltage Interruptions
Radiated Emissions
Conducted Emissions
Harmonic Current Emissions
Voltage Fluctuations & Flicker
Voltage Dips and Interruptions
EN 60950-1/A12:2011
EN 60601-1/A2:1995 , EN 60601-1/A2:2006
-
EN 61000-4-2, ±8kV Contact Discharge ,   ±8kV Air Discharge
EN 61000-4-3, 80MHz-2.5GHz, 10/m, 80% AM
EN 61000-4-4, ±2 kV
EN 61000-4-5, ± 1 kV Common Mode ± 2 kV Differential Mode
EN 61000-4-6, .15 to 80MHz, 10V, 80% AM
EN 61000-4-11, 95% Reduction, 5s
EN 55011/22, Class B
EN 55011/22, Class B
EN 61000-3-2
EN 61000-3-3
EN 61000-4-11, 30% Reduction 
500ms, 95% Reduction, 10ms
60% Reduction, 1s (Criteria B) 
95% Reductions, 5000ms

ENVIRONMENTAL SPECIFICATIONS

Ambient Operating
Temperature Range
Ambient Storage Temp. Range
Temperature Coefficient
0° C to + 70° C
Derating: See Power Rating Chart on Data Sheet
– 40° C to + 85° C
Outputs 1 – 4: 0.02% /°C

GENERAL SPECIFICATIONS

Means of Protection
Primary to Secondary
Primary to Ground
Secondary to Ground
Dielectric Strength(10)
Reinforced Insulation
Basic Insulation
Operational Insulation
Leakage Current
Earth Leakage
Touch Current
Mean-Time Between Failures
Weight
-
2MOPP (Means of Patient Protection)
1MOPP (Means of Patient Protection)
Operational Insulation(Consult factor for 1MOOP or 1 MOPP)
(See Datasheet)
5656 VDC, Primary to Secondary, 1 Sec.
2545 VDC, Primary to Ground, 1 Sec.
707 VDC, Secondary to Ground, 1 Sec.
-
less than 300uA NC, less than 1000uA SFC
less than 100uA NC, less than 500uA SFC
100,000 Hours min., MIL-HDBK-217F, 25° C, GB
0.49 Lbs. Open Frame
0.85 Lbs. Chassis and Cover

All specifications are maximum at 25° C, unless otherwise stated, may vary by model and are subject to change without notice.       

If your in need of a Semi Custom AC/DC DC/DC  Medical Power Supply or Industrial Power Supply then please contact us  so we can assist you further 